502078bebf
gates / gates (push) Successful in 20s
Window 2 (01:56-02:36Z) caught the off-site nightly at 02:15:03Z — snaps 1->2, last_run advanced with no prompting. Window 1 had already caught the local legs (db-dump 00:30:25Z, tier + fill-watch 01:30:19Z). My 04:15 prediction was wrong in the other direction; recorded rather than quietly fixed. What should have fired and did not: NOTHING. Six registered jobs were never seen in the log and none is a finding — four are quiet by construction (scheduler.go:267, quiet := job.Interval <= 30s) and two run every 6h, outside a 4h window. Checked the source rather than filing four phantom defects. What fired and should not have: nothing. No alert, notification, email or digest. The only WARN lines in five hours were three of mine. Observation kept: offbox-backup ticked twice 62s apart and produced ONE new snapshot — the second silently dropped by the single-flight, which is correct for the nightly path and is the same mechanism that produced R-234 on the manual path.