fa0ecb2cd7
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01GzammAMzsJTgpQHqxwM2bC
44 lines
3.0 KiB
Markdown
44 lines
3.0 KiB
Markdown
# felhom.eu — task reports
|
|
|
|
> **Overwrite** this file with a summary of the most recent task only (uniform with the other repos; not cumulative). The cumulative hub history lives in [hub/CHANGELOG.md](hub/CHANGELOG.md); the scripts history lives in [scripts/CHANGELOG.md](scripts/CHANGELOG.md).
|
|
|
|
## RUNBOOK-peti-return — Phase 0a/1 executed, **STOPPED at Gate P1 for a ruling** — 2026-07-13
|
|
|
|
Operational run, read-only throughout (hub API with the bearer + a `hub.db` snapshot queried on
|
|
180 and deleted after). Nothing signed, pushed, or changed on any box or in the hub. Full
|
|
evidence: `documentation/pilot/RUNBOOK-peti-return-2026-07-13.md` §EXECUTION RECORD.
|
|
|
|
### Gate P1 FAILS — controller 0.115.0 is NOT converging to the 0.122.0 floor
|
|
|
|
- The hub **is serving** the floor (DB floor 0.122.0; agent 0.81.0 ≥ MinAgent 0.81.0; no HELD
|
|
lines in live hub logs). The stall is box-side.
|
|
- Self-update worked until 07-11 13:38 (0.110→0.112→0.113→0.115), then the **controller→agent
|
|
:8443 channel died at 07-11 14:01** ("no route to host 192.168.1.170:8443") and is **still
|
|
refusing today** (fresh `agent_channel_unreachable` 16:15 local, hours after host-reports
|
|
resumed). The floor auto-update delegates the container swap to the agent over that channel;
|
|
a failed attempt is persisted **once-per-floor** (anti-flapping) and never retried.
|
|
- **Root cause below it: the cluster split the runbook itself declares a STOP.** The agent's node
|
|
("proxmox", 128 GB RAM) rebooted ~3.5 h ago and reports **0 guests**; the guest's controller
|
|
reports 4.2 days uptime on an i5-2500/8 GB — **the felhom guest is not on the node the agent is
|
|
enrolled on** (proxmox1/proxmox2 shape; single host row verified).
|
|
|
|
### Phase 0a record (the notification-pipeline first-real-customer answer)
|
|
|
|
- Claim code: issued gen 1 + **emailed 2026-07-12 16:49:09Z**, NOT yet claimed.
|
|
- **FINDING P1-F1: the motioneye 100 % warning NEVER emailed Peti** — all 16 `storage_fill_critical`
|
|
notifications went operator-channel only; no `customer_notifications` row exists pre-claim.
|
|
Follow-up task: define intended pre-claim customer-notification behavior.
|
|
- Collateral: P1-F2 agent local vzdump of 9201 fails every cycle (`not a UPID: "OK"` — cross-node
|
|
vmid); P1-F3 `wg-handshake-read` DEGRADED (wg tools missing on his node); P1-F4 the MinAgent
|
|
conditional floor is served from last-known agent_version with no freshness check (floor was
|
|
served while his agent was 40 h dead, guaranteeing the failed swap). motioneye VG: 1.2 TB at
|
|
99.66 % (4.09 GB free).
|
|
|
|
### Ruling needed (all queued in the runbook doc)
|
|
|
|
1. Cluster split: migrate guest back / move the agent / accelerate agent-follows-guest.
|
|
2. Post-heal convergence path: floor bump (0.125.0 earmarked), manual trigger, or state clear.
|
|
3. Optional: hub controller-log pull to confirm the stall variant (CC did not trigger — write op).
|
|
4. Phase 0b/0c (message Peti, call slot) — Viktor, unaffected. Phase 4 rotations independent —
|
|
can proceed on GO.
|