RUNBOOK-peti-return — Phase 0a/1 executed, STOPPED at Gate P1 for a ruling — 2026-07-13

Operational run, read-only throughout (hub API with the bearer + a hub.db snapshot queried on 180 and deleted after). Nothing signed, pushed, or changed on any box or in the hub. Full evidence: documentation/pilot/RUNBOOK-peti-return-2026-07-13.md §EXECUTION RECORD.

Gate P1 FAILS — controller 0.115.0 is NOT converging to the 0.122.0 floor

  • The hub is serving the floor (DB floor 0.122.0; agent 0.81.0 ≥ MinAgent 0.81.0; no HELD lines in live hub logs). The stall is box-side.
  • Self-update worked until 07-11 13:38 (0.110→0.112→0.113→0.115), then the controller→agent :8443 channel died at 07-11 14:01 ("no route to host 192.168.1.170:8443") and is still refusing today (fresh agent_channel_unreachable 16:15 local, hours after host-reports resumed). The floor auto-update delegates the container swap to the agent over that channel; a failed attempt is persisted once-per-floor (anti-flapping) and never retried.
  • Root cause below it: the cluster split the runbook itself declares a STOP. The agent's node ("proxmox", 128 GB RAM) rebooted ~3.5 h ago and reports 0 guests; the guest's controller reports 4.2 days uptime on an i5-2500/8 GB — the felhom guest is not on the node the agent is enrolled on (proxmox1/proxmox2 shape; single host row verified).

Phase 0a record (the notification-pipeline first-real-customer answer)

  • Claim code: issued gen 1 + emailed 2026-07-12 16:49:09Z, NOT yet claimed.
  • FINDING P1-F1: the motioneye 100 % warning NEVER emailed Peti — all 16 storage_fill_critical notifications went operator-channel only; no customer_notifications row exists pre-claim. Follow-up task: define intended pre-claim customer-notification behavior.
  • Collateral: P1-F2 agent local vzdump of 9201 fails every cycle (not a UPID: "OK" — cross-node vmid); P1-F3 wg-handshake-read DEGRADED (wg tools missing on his node); P1-F4 the MinAgent conditional floor is served from last-known agent_version with no freshness check (floor was served while his agent was 40 h dead, guaranteeing the failed swap). motioneye VG: 1.2 TB at 99.66 % (4.09 GB free).

Ruling needed (all queued in the runbook doc)

  1. Cluster split: migrate guest back / move the agent / accelerate agent-follows-guest.
  2. Post-heal convergence path: floor bump (0.125.0 earmarked), manual trigger, or state clear.
  3. Optional: hub controller-log pull to confirm the stall variant (CC did not trigger — write op).
  4. Phase 0b/0c (message Peti, call slot) — Viktor, unaffected. Phase 4 rotations independent — can proceed on GO.