b4dcf4b373
gates / gates (push) Successful in 6m35s
plugswitch.py refuses 'off' unless 20 s of readings show the N100 is already off (standby + 1 W, no ping); 7 tests, each check red-proofed. By hand: guest shutdown 12 s, host off, 0.0 W; the hub stayed silent and 'ONLINE' for 18 min; plug off/on did not start the N100, its power button did (dashboard in 42 s). Wall figures into SIZING.md 4 and sizing.json power (8.5 / 20.7 / 0.0 W).
28 lines
858 B
Plaintext
28 lines
858 B
Plaintext
plug_off_request 2026-10-13T17:03:02.016Z
|
|
check 0s watts=0.0 ping=none
|
|
check 2s watts=0.0 ping=none
|
|
check 8s watts=0.0 ping=none
|
|
check 14s watts=0.0 ping=none
|
|
check 16s watts=0.0 ping=none
|
|
REFUSED: only 16 s of readings, need 20 s
|
|
rc=2
|
|
plug_off_done 2026-10-13T17:03:24.604Z
|
|
plug_on_request 2026-10-13T17:03:34.609Z
|
|
switch=on watts=0
|
|
rc=0
|
|
plug_on_done 2026-10-13T17:03:35.060Z
|
|
plug_off_request 2026-10-13T17:03:44.114Z
|
|
check 0s watts=0.0 ping=none
|
|
check 3s watts=0.0 ping=none
|
|
check 9s watts=0.0 ping=none
|
|
check 16s watts=0.0 ping=none
|
|
check 22s watts=0.0 ping=none
|
|
allowed: 5 readings over 22 s, all below 1 W, no ping answer
|
|
switch=off watts=0
|
|
rc=0
|
|
plug_off_done 2026-10-13T17:04:17.386Z
|
|
plug_on_request 2026-10-13T17:04:27.392Z
|
|
switch=on watts=0
|
|
rc=0
|
|
plug_on_done 2026-10-13T17:04:32.890Z
|