b03a105375
gates / gates (push) Successful in 17s
Hub only. No controller change, no agent change, no wire change — nothing to bake. demo-hp untouched: the operator is re-deploying it this evening. R-323 — the five-word phrase is „Tulajdonosi jelmondat". It was „Visszaállító jelszó": one word from the name retired last week, and false besides — it restores nothing, it proves the account owns the box being bound. Five sites, all in the hub; felhom-controller and felhom-agent carry the name nowhere, so no halt and no bake. Both suggested names were rejected with reasons: „Fiókjelszó" would collide with the dashboard login (a DIFFERENT real secret), and „Összekötési jelszó" would leave the two factors on this page separated only by kód-versus-jelszó — the exact shape being removed, since the other factor is the „Párosító kód". The chosen name differs on both axes, stem and noun. Naming only; the acceptance pin drives the real handler. R-324 — the hub's customer copy is under a guard for the first time. Retired names banned across all 95 hub files; retrieval stems registered in four declared customer surfaces. The selftest found a defect in its own instrument on the first run. One shared vocabulary in scripts/, drift-checked into the controller gate rather than copied (R-325 removes the scaffold). R-321 — a machine we told to be quiet is no longer reported as dead, and it was two doors, not one: because the state is RECORDED rather than deleted, the morning deadline check can skip it too. A deleted state returns "", which is not "down" — R-195's shape returning through a second door. The clock runs from the report the hub can see, so re-enabling starts it there and emits no recovery for an outage that never happened. Three red-proofs; the one that matters showed a genuinely dead machine sitting at "disabled" when the suppression was made unconditional. R-326 — "which claims are unproven" is answerable by a command now. The nine I have been repeating was the count of claims the 9 August pass DOWNGRADED, not the count of unproven ones. The real figures: 55 claims, 23 walked, 32 not — and only 6 of those 32 cite evidence. Its first run found a stale claim (R-327).
253 lines
8.8 KiB
Go
253 lines
8.8 KiB
Go
package monitor
|
|
|
|
import (
|
|
"fmt"
|
|
"log"
|
|
"strings"
|
|
"sync"
|
|
"time"
|
|
|
|
"gitea.dooplex.hu/admin/felhom-hub/internal/store"
|
|
)
|
|
|
|
// EventNotifyFunc is called after a hub-generated event is saved,
|
|
// to trigger notification dispatch. Keeps monitor decoupled from notify.
|
|
type EventNotifyFunc func(customerID, eventType, severity, message, detailsJSON, source string)
|
|
|
|
// StateDisabled is the state of a customer whose box we DELIBERATELY told to stop reporting.
|
|
//
|
|
// R-321. Switching a box's hub reporting off is a supported product state: the controller sends one
|
|
// final report carrying health.status = "disabled" (felhom-controller
|
|
// `cmd/controller/main.go:1253`) and then goes quiet BY DESIGN. That status is parsed and persisted
|
|
// (`store.go:953-955` → `reports.health_status`), reaches this checker on every pass inside
|
|
// `CustomerSummary.HealthStatus` (`store.go:40`), and the operator roll-up already renders such a
|
|
// customer as `disabled` (`web/rollup.go:25`).
|
|
//
|
|
// This checker ignored it and measured only the AGE of the last report — so a machine we asked to be
|
|
// quiet went stale at 30 minutes, down at 60, and e-mailed the operator twice about an outage we
|
|
// caused on purpose. That is the false alarm that teaches people to ignore the channel, and it is a
|
|
// sibling of R-195, where the guard that should have covered a customer was keyed off the wrong fact.
|
|
//
|
|
// It is a STATE here rather than a deletion (the `blocked` branch below deletes) because other
|
|
// checkers consult GetState: CheckBackupDeadlines skips a customer that is "down", and a DELETED
|
|
// state returns "" — which is not "down", so a disabled box would have gone on alarming
|
|
// `expected_backup_missed` from a different function. Exactly the R-195 shape returning through a
|
|
// second door.
|
|
const StateDisabled = "disabled"
|
|
|
|
// StalenessChecker monitors customer report freshness and generates
|
|
// node_stale / node_down / node_recovered events on state transitions.
|
|
type StalenessChecker struct {
|
|
store *store.Store
|
|
threshold time.Duration // "stale" after this duration (default 30m)
|
|
downAfter time.Duration // "down" after this duration (2x threshold)
|
|
logger *log.Logger
|
|
onEvent EventNotifyFunc
|
|
|
|
mu sync.Mutex
|
|
states map[string]string // customerID → "ok" | "stale" | "down"
|
|
downtimeStart map[string]time.Time // customerID → when node first became unreachable
|
|
}
|
|
|
|
// NewStalenessChecker creates a checker and initializes state from current data.
|
|
// No events are generated during initialization (binding #12).
|
|
// onEvent is called after each hub-generated event is saved (may be nil).
|
|
func NewStalenessChecker(s *store.Store, threshold time.Duration, onEvent EventNotifyFunc, logger *log.Logger) *StalenessChecker {
|
|
sc := &StalenessChecker{
|
|
store: s,
|
|
threshold: threshold,
|
|
downAfter: 2 * threshold,
|
|
logger: logger,
|
|
onEvent: onEvent,
|
|
states: make(map[string]string),
|
|
downtimeStart: make(map[string]time.Time),
|
|
}
|
|
|
|
// Seed states from current report timestamps — no events on init
|
|
customers, err := s.GetCustomers()
|
|
if err != nil {
|
|
logger.Printf("[WARN] Staleness checker: failed to seed states: %v", err)
|
|
return sc
|
|
}
|
|
|
|
var okCount, staleCount, downCount int
|
|
for _, c := range customers {
|
|
if s.IsCustomerBlocked(c.CustomerID) {
|
|
continue
|
|
}
|
|
age := time.Since(c.ReceivedAt)
|
|
switch {
|
|
case age > sc.downAfter:
|
|
sc.states[c.CustomerID] = "down"
|
|
downCount++
|
|
case age > sc.threshold:
|
|
sc.states[c.CustomerID] = "stale"
|
|
staleCount++
|
|
default:
|
|
sc.states[c.CustomerID] = "ok"
|
|
okCount++
|
|
}
|
|
}
|
|
logger.Printf("[INFO] Staleness checker initialized: %d ok, %d stale, %d down", okCount, staleCount, downCount)
|
|
|
|
return sc
|
|
}
|
|
|
|
// Check evaluates all customers and emits events on state transitions.
|
|
// Should be called periodically (every 60s).
|
|
func (sc *StalenessChecker) Check() {
|
|
customers, err := sc.store.GetCustomers()
|
|
if err != nil {
|
|
sc.logger.Printf("[WARN] Staleness check failed: %v", err)
|
|
return
|
|
}
|
|
|
|
sc.mu.Lock()
|
|
defer sc.mu.Unlock()
|
|
|
|
// Track which customers are still present (to clean up removed ones)
|
|
seen := make(map[string]bool, len(customers))
|
|
|
|
for _, c := range customers {
|
|
seen[c.CustomerID] = true
|
|
|
|
if sc.store.IsCustomerBlocked(c.CustomerID) {
|
|
delete(sc.states, c.CustomerID)
|
|
continue
|
|
}
|
|
|
|
// R-321 — a machine we told to be quiet is not a machine that died.
|
|
//
|
|
// The age-based transition is skipped entirely; no stale, no down, no e-mail. The state is
|
|
// RECORDED rather than deleted so the deliberate silence is visible to anything that asks
|
|
// (see StateDisabled). `downtimeStart` is cleared on ENTRY so that a later, genuine outage
|
|
// cannot compute its duration from a clock that started before we asked for the silence.
|
|
//
|
|
// The discriminator is the box's OWN last word, not an inference: it said `disabled` on the
|
|
// way out. LIMIT, stated rather than hidden: if reporting is re-enabled and the box then
|
|
// fails to report at all, the hub still sees only that final `disabled` report and keeps
|
|
// suppressing. The hub cannot distinguish that from "still switched off" — its view changes
|
|
// only when a report arrives. This is why the state is made VISIBLE: an operator who
|
|
// re-enabled a box and still sees `disabled` is being told it has not come back.
|
|
if strings.EqualFold(c.HealthStatus, StateDisabled) {
|
|
if sc.states[c.CustomerID] != StateDisabled {
|
|
sc.states[c.CustomerID] = StateDisabled
|
|
delete(sc.downtimeStart, c.CustomerID)
|
|
}
|
|
continue
|
|
}
|
|
|
|
age := time.Since(c.ReceivedAt)
|
|
var newState string
|
|
switch {
|
|
case age > sc.downAfter:
|
|
newState = "down"
|
|
case age > sc.threshold:
|
|
newState = "stale"
|
|
default:
|
|
newState = "ok"
|
|
}
|
|
|
|
oldState := sc.states[c.CustomerID]
|
|
if oldState == "" || oldState == StateDisabled {
|
|
// New customer — set state without event.
|
|
//
|
|
// R-321 adds the re-enabled case to the SAME branch, deliberately. A box coming back
|
|
// from a deliberate silence is a first observation, not a recovery: emitting here would
|
|
// send `node_recovered` for an outage that never happened — and would do it every time
|
|
// an operator switched reporting back on.
|
|
//
|
|
// THE RE-ENABLEMENT CLOCK, and this is the judgement: it is the age of the report the
|
|
// hub can actually see. For a box that reports on re-enabling, that report IS the
|
|
// re-enablement, so the clock starts there and scenario D (re-enabled, then genuinely
|
|
// quiet) alarms on a normal schedule timed from the moment it came back. Timing from the
|
|
// last report BEFORE the switch-off would fire an instant stale/down for a quiet period
|
|
// we asked for — a false alarm produced by fixing false alarms.
|
|
sc.states[c.CustomerID] = newState
|
|
continue
|
|
}
|
|
|
|
if oldState == newState {
|
|
continue
|
|
}
|
|
|
|
// State transition — emit event
|
|
sc.states[c.CustomerID] = newState
|
|
if newState == "stale" && oldState == "ok" {
|
|
// Record when node first became unreachable
|
|
sc.downtimeStart[c.CustomerID] = time.Now()
|
|
}
|
|
downtimeDur := age
|
|
if newState == "ok" {
|
|
if t, ok := sc.downtimeStart[c.CustomerID]; ok {
|
|
downtimeDur = time.Since(t)
|
|
}
|
|
delete(sc.downtimeStart, c.CustomerID)
|
|
}
|
|
sc.emitTransition(c.CustomerID, oldState, newState, downtimeDur)
|
|
}
|
|
|
|
// Clean up customers that no longer have reports
|
|
for id := range sc.states {
|
|
if !seen[id] {
|
|
delete(sc.states, id)
|
|
delete(sc.downtimeStart, id)
|
|
}
|
|
}
|
|
}
|
|
|
|
// GetState returns the current staleness state for a customer.
|
|
func (sc *StalenessChecker) GetState(customerID string) string {
|
|
sc.mu.Lock()
|
|
defer sc.mu.Unlock()
|
|
s := sc.states[customerID]
|
|
if s == "" {
|
|
return "unknown"
|
|
}
|
|
return s
|
|
}
|
|
|
|
func (sc *StalenessChecker) emitTransition(customerID, oldState, newState string, age time.Duration) {
|
|
var eventType, severity, message string
|
|
|
|
switch {
|
|
case newState == "stale":
|
|
eventType = "node_stale"
|
|
severity = "warning"
|
|
message = "No report received for " + formatDuration(age)
|
|
case newState == "down":
|
|
eventType = "node_down"
|
|
severity = "error"
|
|
message = "No report received for " + formatDuration(age)
|
|
case newState == "ok" && (oldState == "stale" || oldState == "down"):
|
|
eventType = "node_recovered"
|
|
severity = "info"
|
|
message = "Reports resumed (was " + oldState + " for " + formatDuration(age) + ")"
|
|
default:
|
|
return
|
|
}
|
|
|
|
sc.logger.Printf("[INFO] Staleness: %s %s → %s (%s)", customerID, oldState, newState, eventType)
|
|
|
|
if _, err := sc.store.SaveEvent(customerID, eventType, severity, message, "{}", "hub"); err != nil {
|
|
sc.logger.Printf("[WARN] Failed to save staleness event for %s: %v", customerID, err)
|
|
return
|
|
}
|
|
|
|
if sc.onEvent != nil {
|
|
sc.onEvent(customerID, eventType, severity, message, "{}", "hub")
|
|
}
|
|
}
|
|
|
|
func formatDuration(d time.Duration) string {
|
|
if d < time.Hour {
|
|
return fmt.Sprintf("%dm", int(d.Minutes()))
|
|
}
|
|
h := int(d.Hours())
|
|
m := int(d.Minutes()) % 60
|
|
if m == 0 {
|
|
return fmt.Sprintf("%dh", h)
|
|
}
|
|
return fmt.Sprintf("%dh%dm", h, m)
|
|
}
|