Power-off spike (Part A) on the N100: plugswitch, wall-power figures, the hub's view
plugswitch.py refuses 'off' unless 20 s of readings show the N100 is already off (standby + 1 W,
no ping); 7 tests, each check red-proofed. By hand: guest shutdown 12 s, host off, 0.0 W; the hub
stayed silent and 'ONLINE' for 18 min; plug off/on did not start the N100, its power button did
(dashboard in 42 s). Wall figures into SIZING.md 4 and sizing.json power (8.5 / 20.7 / 0.0 W).
2026-10-13 19:15:08 +02:00

28 lines
858 B
Plaintext

plug_off_request 2026-10-13T17:03:02.016Z
check 0s watts=0.0 ping=none
check 2s watts=0.0 ping=none
check 8s watts=0.0 ping=none
check 14s watts=0.0 ping=none
check 16s watts=0.0 ping=none
REFUSED: only 16 s of readings, need 20 s
rc=2
plug_off_done 2026-10-13T17:03:24.604Z
plug_on_request 2026-10-13T17:03:34.609Z
switch=on watts=0
rc=0
plug_on_done 2026-10-13T17:03:35.060Z
plug_off_request 2026-10-13T17:03:44.114Z
check 0s watts=0.0 ping=none
check 3s watts=0.0 ping=none
check 9s watts=0.0 ping=none
check 16s watts=0.0 ping=none
check 22s watts=0.0 ping=none
allowed: 5 readings over 22 s, all below 1 W, no ping answer
switch=off watts=0
rc=0
plug_off_done 2026-10-13T17:04:17.386Z
plug_on_request 2026-10-13T17:04:27.392Z
switch=on watts=0
rc=0
plug_on_done 2026-10-13T17:04:32.890Z