Three I1/I1-pair violations in ~5 minutes, all "expected event absent". Recorded as an OPEN observation, NOT a finding: the system was mid-abuse when it was seen, and a verdict taken on a system being hammered is worth little. Established: it is not hub-side suppression and not a truncated log. The hub pod has 0 restarts over 43h and the controller's own log matches it line for line, so the events were never emitted. It is specific to the backup_target_* pair - the generic storage_disconnected/reconnected pair for the other drive kept firing normally throughout the same window. Also sampled, and the more serious half if it survives quiescence: mentes reads bound_under_parent=False while the backup-target state simultaneously reports degraded=false. Those cannot both be right - a false healthy on the backup target is I5/I6's failure mode. NOT established: whether the pair recovers once cycling stops (the harness detaches every ~2 min; a customer does not), whether the 02:25:37 controller restart is implicated, and whether the degraded=false sample was transient. Disposition written into the doc: after the run ends, quiesce with both drives attached, then do ONE slow detach/reattach and see whether the pair fires. That distinguishes "does not survive rapid cycling" from "the target alarm has silently stopped working", which would be severe.