R-549 (operator ruling A): controllerStatus hardcoded 30m/1h while both
staleness checkers and hostStatus read alerting.stale_threshold. Moving the
threshold to 45m would have painted a customer amber 15 minutes before the
alarm could fire - the second definition rollup.go's header forbids. It now
reads the same value, down at 2x. Both 'checker initialized' log lines print
the threshold, which no line did before.
R-539 (ruling 3 of 2026-09-16): controller_slow_crashloop (warning,
operator-only), minted when the agent's slow_crashloop_since moves, with the
fast sibling's first-sight rule.
R-550: restore_interrupted (warning, for the household) allowlisted with a
Hungarian customer message.
Red-proofs, each seen failing then passing: the status test with the old
hardcoded numbers; the checker test with the movement branch removed; the
operator-only test with the registration removed; the household-message test
with the Hungarian entry removed (asserted on the SUBJECT - the body
legitimately repeats the raw message, which my first version of the test
mistook for a fallback).
go build/vet/test ./... green, 18 packages.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_0159rPz1ZhFKsS53msqPYxtS
Hub only. No controller change, no agent change, no wire change — nothing to bake.
demo-hp untouched: the operator is re-deploying it this evening.
R-323 — the five-word phrase is „Tulajdonosi jelmondat". It was „Visszaállító
jelszó": one word from the name retired last week, and false besides — it restores
nothing, it proves the account owns the box being bound. Five sites, all in the hub;
felhom-controller and felhom-agent carry the name nowhere, so no halt and no bake.
Both suggested names were rejected with reasons: „Fiókjelszó" would collide with the
dashboard login (a DIFFERENT real secret), and „Összekötési jelszó" would leave the
two factors on this page separated only by kód-versus-jelszó — the exact shape being
removed, since the other factor is the „Párosító kód". The chosen name differs on
both axes, stem and noun. Naming only; the acceptance pin drives the real handler.
R-324 — the hub's customer copy is under a guard for the first time. Retired names
banned across all 95 hub files; retrieval stems registered in four declared customer
surfaces. The selftest found a defect in its own instrument on the first run. One
shared vocabulary in scripts/, drift-checked into the controller gate rather than
copied (R-325 removes the scaffold).
R-321 — a machine we told to be quiet is no longer reported as dead, and it was two
doors, not one: because the state is RECORDED rather than deleted, the morning
deadline check can skip it too. A deleted state returns "", which is not "down" —
R-195's shape returning through a second door. The clock runs from the report the hub
can see, so re-enabling starts it there and emits no recovery for an outage that never
happened. Three red-proofs; the one that matters showed a genuinely dead machine
sitting at "disabled" when the suppression was made unconditional.
R-326 — "which claims are unproven" is answerable by a command now. The nine I have
been repeating was the count of claims the 9 August pass DOWNGRADED, not the count of
unproven ones. The real figures: 55 claims, 23 walked, 32 not — and only 6 of those 32
cite evidence. Its first run found a stale claim (R-327).