I1-I11 are CORRECTNESS invariants: they answer 'is the system telling the truth
this cycle'. All 586 of them passed in run 1 while nothing at all watched whether
disk usage, snapshot count, log volume, fd count or RSS climbs. Accumulation is
exactly what depth was for, and it was missing from the invariant list.
Adds c10growth.py (Campaign 2's controller_rss.tsv precedent, widened to 19
metrics) sampling every 90s as a SEPARATE process, so the in-flight run 2 did not
have to be restarted. Attributes every sample to a cycle by reading the runner's
status.txt, and records NA rather than dying when the box is down during a
hard-reset or reboot atom.
c10growth_report.py turns it into Campaign 2's table shape (start/end/min/max/
slope-per-cycle) and splits verdicts by class: growth in RSS/fd/volumes/images/
restarts is a LEAK; growth in backup storage or the qcow2 is expected
accumulation, reported with a projection to cycle 45.
Caught a bug in the sampler itself on the first analysis: MENTES_USED_MB appeared
to jump 623 -> 5667 MB, which is exactly ROOT_USED_MB — when a drive is detached,
/mnt/<name> reverts to a plain directory on root and df silently reports the ROOT
filesystem. The same class of error as the agent's exactMount check, in the
measurement code. Gated on mountpoint and red-proofed both ways: a real mount
returns a number, a non-mount returns NA.
Ran the soak on the Phase A rig. Ended on its own deadline — no watchdog halt,
no atom exception, no I11 breach.
I1 28+28 pairs, I2 28+28 pairs, I3 56, I4 56, I5/I6 28 each, I7 28, I10 135,
I11 28. Zero violations. The row counts are themselves the no-silent-skip check:
I3/I4 twice per cycle (both drives), I10 = 5 secret-class fields x 27, REBOOT on
cycles 7/14/21 only.
I7 is the headline: 28 restores, 28 correct discriminators — never stale, never
empty. RTO (Tier 1, rallly, 66 MB): min 38.8s, median 42.0s, p90 42.5s, max
44.3s. That is the S band's lower end ONLY; the 5.5s spread over 28 runs says
fixed work dominates, so nothing extrapolates to M or L. RPO not measured.
Every atom and invariant was proven BY HAND before automation — the runner
asserts nothing that was not first observed live.
Caught a Phase A gap before starting: no app had HDD_PATH, so all data sat on the
system disk and I3 could never have fired. Deployed calibre-web onto adatok
first; otherwise the run would have produced 27 green cycles that tested nothing
cross-drive.
Investigated and DISPROVED a suspected defect (audit 5.2): /api/disks reports
state=attached for a physically absent drive, and intermediary.go:230 really does
compute presence from State=="attached". It is inert — planDriveGates only gates
paths under /mnt/felhom-drives/ and uses BoundUnderParent there, which was
correctly false. The gate fired; the storage page showed "Meghajtó leválasztva".
No R-n minted.
Honest gaps: 6 of ~12 atom families ran. Not run — Tier 3 (structurally
un-isolatable), abort-fs-in-place, kill-agent-mid-backup, hard-reset-mid-write,
reboot-VM, both concurrency atoms, fill-drive-near-full. I8 not checked, I9 not
automated (cited from the tester-gate run, not re-claimed). kill_controller is
NOT mid-backup and reboot_guest never interleaved with a detach. 27 cycles does
not answer the brief's question about drift at the thirty-eighth.
Teardown still OWED, including hub customer c10-soak (disposition: DELETE).