Commit Graph

2 Commits

Author SHA1 Message Date
admin 95d293b911 Bench: --plug hp — the HP t740 (demo-hp) is on a metered plug too
gates / gates (push) Successful in 6m51s
plugmeter.py and plugswitch.py take --plug n100|hp (plug.json / plug-hp.json, outside the repo).
The HP plug read 23-33 W while the box started its three guests.
2026-10-13 21:29:02 +02:00
admin b4dcf4b373 Power-off spike (Part A) on the N100: plugswitch, wall-power figures, the hub's view
gates / gates (push) Successful in 6m35s
plugswitch.py refuses 'off' unless 20 s of readings show the N100 is already off (standby + 1 W,
no ping); 7 tests, each check red-proofed. By hand: guest shutdown 12 s, host off, 0.0 W; the hub
stayed silent and 'ONLINE' for 18 min; plug off/on did not start the N100, its power button did
(dashboard in 42 s). Wall figures into SIZING.md 4 and sizing.json power (8.5 / 20.7 / 0.0 W).
2026-10-13 19:15:08 +02:00