#!/usr/bin/env python3
"""plugcut.py — a REAL power cut on a bench machine, with three ways back on.
~/.venvs/plugmeter/bin/python scripts/bench/plugcut.py --plug hp --off-seconds 10 --i-mean-a-power-cut \
[--long] [--log DIR]
This is NOT plugswitch.py. `plugswitch.py off` stays „not a power-cut button" (it refuses a running machine).
This tool cuts a running machine on purpose, so it is fenced:
- only the plug `hp` (the N100's plug only with --allow-n100, the operator's „N100: B"; nothing else exists);
- only with --i-mean-a-power-cut;
- --off-seconds 1..60; up to 3600 only with --long.
Three ways the power comes back, so a dead DooPlex or a killed tool cannot leave a machine without power:
1. THE PLUG'S OWN COUNTDOWN (data point 9, countdown_1): sent in the SAME command as the relay off, then read
back. If the read-back does not show the countdown running, the relay is switched on at once.
2. A WATCHDOG PROCESS, started (detached, own session) BEFORE the off: it sleeps off-seconds + 15 s and then
switches the relay on. It survives this process being killed.
3. `finally:` in this process: the relay is switched on (and read back) whatever happened after the off.
One line per action (UTC, plug, relay, countdown) to stdout and, with --log DIR, to DIR/plugcut.log.
The key and the device id are never printed. Pinned by scripts/bench/test_plugcut.py.
"""
import argparse, os, subprocess, sys, time
from datetime import datetime, timezone
sys.path.insert(0, os.path.dirname(os.path.abspath(__file__)))
from plugswitch import load, device # noqa: E402 (same plug files, same connection settings)
MAX_S = 60
MAX_LONG_S = 3600
WATCHDOG_EXTRA_S = 15
LOG_DIR = None
def say(plug, msg):
line = f'{datetime.now(timezone.utc).strftime("%Y-%m-%dT%H:%M:%S.%f")[:-3]}Z {plug} {msg}'
print(line, flush=True)
if LOG_DIR:
with open(os.path.join(LOG_DIR, 'plugcut.log'), 'a') as f:
f.write(line + '\n')
def refuse_reason(a):
"""None when allowed, else why not. Pure: tested without a plug."""
if a.plug not in ('hp', 'n100'):
return f'unknown plug {a.plug!r}'
if a.plug == 'n100' and not a.allow_n100:
return 'the N100 is not cut unless the operator said „N100: B" (--allow-n100)'
if not a.i_mean_a_power_cut:
return 'this cuts a running machine: add --i-mean-a-power-cut'
if a.off_seconds < 1:
return 'off-seconds must be at least 1'
limit = MAX_LONG_S if a.long else MAX_S
if a.off_seconds > limit:
return f'off-seconds {a.off_seconds} is over {limit}' + ('' if a.long else ' (longer needs --long)')
return None
def relay(dev):
s = dev.status()
d = s.get('dps', {}) if isinstance(s, dict) else {}
return d.get('1'), d.get('9')
def start_watchdog(plug, after_s):
"""Detached process that switches the relay on after `after_s` s. Returns its pid."""
args = [sys.executable, os.path.abspath(__file__), '--watchdog', str(after_s), '--plug', plug]
if LOG_DIR:
args += ['--log', LOG_DIR]
p = subprocess.Popen(args, stdin=subprocess.DEVNULL, stdout=subprocess.DEVNULL, stderr=subprocess.DEVNULL,
start_new_session=True)
return p.pid
def turn_on_verified(dev, plug, who, tries=5):
for i in range(tries):
try:
dev.turn_on()
on, cd = relay(dev)
say(plug, f'{who}: relay={"on" if on else "off?"} countdown={cd}')
if on:
return True
except Exception as e: # a slow plug read is late, not lost — try again
say(plug, f'{who}: try {i + 1} failed ({type(e).__name__})')
time.sleep(2)
return False
def cut(dev, plug, off_s, watchdog=start_watchdog, sleep=time.sleep, now=time.monotonic):
"""The cut. Returns 0 when the relay is on again at the end."""
pid = watchdog(plug, off_s + WATCHDOG_EXTRA_S)
say(plug, f'watchdog armed (pid {pid}, relay on after {off_s + WATCHDOG_EXTRA_S} s at the latest)')
try:
dev.set_multiple_values({'1': False, '9': int(off_s)})
say(plug, f'CUT: relay off + countdown {off_s} s sent in one command')
on, cd = relay(dev)
say(plug, f'read back: relay={"on" if on else "off"} countdown={cd}')
if on is not False or not cd:
say(plug, 'countdown NOT shown running — switching on now (fail-safe)')
return 0 if turn_on_verified(dev, plug, 'fail-safe') else 1
t0 = now()
sleep(off_s)
while now() - t0 < off_s + 10:
try:
on, cd = relay(dev)
except Exception:
on = None
if on:
say(plug, f'BACK: relay on by the plug countdown, +{now() - t0:.1f} s after the cut')
return 0
sleep(1)
say(plug, 'the countdown did not switch the relay on within off-seconds + 10 s')
return 1
finally:
try:
on, cd = relay(dev)
except Exception:
on = None
if not on:
turn_on_verified(dev, plug, 'finally re-arm')
def main(argv):
global LOG_DIR
ap = argparse.ArgumentParser(description=__doc__.split('\n')[0])
ap.add_argument('--plug', default='hp')
ap.add_argument('--off-seconds', type=int, default=0)
ap.add_argument('--i-mean-a-power-cut', action='store_true')
ap.add_argument('--long', action='store_true')
ap.add_argument('--allow-n100', action='store_true')
ap.add_argument('--log')
ap.add_argument('--watchdog', type=int, help=argparse.SUPPRESS)
a = ap.parse_args(argv)
LOG_DIR = a.log
if a.watchdog is not None: # the detached watchdog: sleep, then make sure the relay is on
time.sleep(a.watchdog)
dev = device(load(a.plug))
on, _ = relay(dev)
if on:
say(a.plug, 'watchdog: relay already on — nothing to do')
return 0
return 0 if turn_on_verified(dev, a.plug, 'WATCHDOG') else 1
why = refuse_reason(a)
if why:
print(f'REFUSED: {why}', file=sys.stderr)
return 2
dev = device(load(a.plug))
return cut(dev, a.plug, a.off_seconds)
if __name__ == '__main__':
sys.exit(main(sys.argv[1:]))