Bench: plugcut.py — a real power cut on the HP with three ways back on; the night's round table written before round 1
gates / gates (push) Successful in 6m45s
gates / gates (push) Successful in 6m45s
This commit is contained in:
@@ -0,0 +1,49 @@
|
||||
# Night 2026-10-13 → 14 — real power cuts on demo-hp, the estimator check, a night of wall power
|
||||
|
||||
Times are **UTC** (the boxes' schedules are in CEST = UTC+2; both are given where it matters). Tier 0 boxes only
|
||||
(`runbooks/target-selection.md`): demo-hp and Tester 1 (VM 341 on it) are cut; the N100 is read only; DooPlex runs
|
||||
the plug tools and reads the hub. Tool: `scripts/bench/plugcut.py` (new). No key, device id or token in this folder.
|
||||
|
||||
## Facts read before round 1 (22:10–22:40)
|
||||
|
||||
| Item | Value |
|
||||
|---|---|
|
||||
| N100 | **ON** — the operator pressed its power button at 21:48:43 (the prompt assumed it stays off). Read only tonight |
|
||||
| HP host | AMD Ryzen Embedded V1756B, 29,994 MiB RAM, swap 8 GiB; guests 9201 (`memory: 25898`), 9202 (25898), VM 341 Tester 1 (8192); 9401 stopped |
|
||||
| HP guest 9201 | 19 containers; 11 apps deployed (Home Assistant and Paperless among them; `paperless-ngx` and `romm` have no running container) |
|
||||
| HP crash guard | `armed: false`, `kernel.panic 0` — tripped by today's 20:13 cut, re-arms 24 h later |
|
||||
| Plug countdown | both plugs have data point 9 `countdown_1` (0–86400 s) and DP 38 `relay_status` = `memory` |
|
||||
| SSH alias | both `ssh demo-hp` and `ssh hp` reach 192.168.0.104 from DooPlex; `nodes.md` is right |
|
||||
|
||||
**The HP's night schedule** (controller log 20:15:57 + agent journal):
|
||||
|
||||
| CEST | UTC | Job | Talks off-box? |
|
||||
|---|---|---|---|
|
||||
| 02:30 | 00:30 | db-dump (Tier 1) | no |
|
||||
| 03:30 | 01:30 | tier2-backup, fill-watch; ep0 prunes households (DooPlex timeline) | ep0 prune — fenced |
|
||||
| 04:15 | 02:15 | offbox-backup (Tier 3, restic → Storage Box) | **yes — fenced** |
|
||||
| ~04:33–04:44 | ~02:33–02:44 | whole-guest vzdump, local (last 3 nights: 04:33, 04:36, 04:38 start, ~5.5 min) | no |
|
||||
| ~04:45 | ~02:45 | OS step (`osupdate` guest + host, ring 0) | **fenced** |
|
||||
| 05:10 / 05:30 / 06:00 | 03:10 / 03:30 / 04:00 | offsite abandon-sweep / proof / integrity | Storage Box — checked live before a cut |
|
||||
| weekly | — | PBS whole-guest → ep0: HP last 2026-10-08 20:34, Tester 1 last 2026-10-11 20:02 (cadence 168 h) — **not due tonight** | — |
|
||||
|
||||
Fences before every cut (§9 rule 3): no `vzdump`, `proxmox-backup-client`, `restic`, `felhom-os-apply`, `apt`/`dpkg`
|
||||
process on the HP host, guest 9201 or Tester 1; no scheduled start within 10 min; ≥ 10 min after the last full recovery.
|
||||
|
||||
## The round table (written 22:45, before round 1)
|
||||
|
||||
| Round | Planned UTC | The cut | Prediction |
|
||||
|---|---|---|---|
|
||||
| A + R1 | 23:00 | idle, 10 s, the countdown spike on the HP plug (the N100 is on: its plug is not a safe bench) | relay back on by the plug countdown; HP starts (BIOS „Previous State", set 20:10 today) in ≤ 40 s to ping; guests in 2–3 min; crash guard `last_boot_unclean: true`; hub `host_crash_restart` mail for demo-hp and Tester 1; no stale/down (well under 45 min) |
|
||||
| R4 | 23:25 | flicker: off 2 s, on 3 s, off 2 s, on | as R1. Risk: the BIOS may treat the second off as a stop during POST and stay off |
|
||||
| R6 | 23:50 | 50 min off (`--long`) | `host_stale` 30–45 min after the last report, for demo-hp AND Tester 1 (and `node_stale` from the controllers); at 50 min no `host_down` yet (90 min); on return: paired `*_recovered` mails + `host_crash_restart`; the 00:30 db-dump is missed while off and caught up after the start |
|
||||
| R5 | 01:00 | 10 s off, 40 s after a power-on | the box is in POST/kernel start; it starts again; nothing is damaged (no guest was running) |
|
||||
| — | 01:20–03:05 | **Part R1/R2 measurement** (no cut): the family set, rest, actions together, rest, across the 01:30 Tier 2, 02:15 Tier 3 and 02:33 vzdump | — |
|
||||
| R2 | 03:15 | 10 s off at mid-import of a second 200-photo Immich upload | Immich DB recovers (postgres WAL replay); the half-import is not shown as done; the controller marks no app done that is not |
|
||||
| R3 | 03:45 | 10 s off during a whole-guest backup started through the product | a `lock: backup` may stay in `pct config 9201` and stop the guest starting (the July finding); predict: the guest **does not** start by itself |
|
||||
| — | 04:15–05:45 | Part R3: the 8 GB box test | — |
|
||||
|
||||
A round may move later; none is dropped without a line here saying why.
|
||||
|
||||
## Rounds (filled as they run)
|
||||
|
||||
@@ -0,0 +1,20 @@
|
||||
14189638d73b22ca70e52ed9c9268ee42e905db1b56968cb81ca2cdd9b8452b8 plant-01.bin
|
||||
78c98745537aa24664ae74361fd3f20309f2934162b58b041e517836bcc417d6 plant-02.bin
|
||||
badddd7dad4214cd6207cb29cfde3edc4e4baab3f63ea23f0c7520a8026992f9 plant-03.bin
|
||||
08ee138f7a6446b8ffee5aed1198921ac3bb016d28d23fd92b4fa4f3c9631269 plant-04.bin
|
||||
ede81bd0d1a89edd367f39bd71345a67178ce49d661b41cf558283da8c6d342f plant-05.bin
|
||||
83d6d2fbd0c8db497216aeddda66c0383d0b9f0f5d527e971f18e4f8f38a96f9 plant-06.bin
|
||||
dbaf2e9ce71cbad9c03208175e9ea582cfe8cdc72da4600301b3dc353a829a7f plant-07.bin
|
||||
24066a276fb71410c1880be8e6d200c949efa55fd7699a70cf4cf0829c66f545 plant-08.bin
|
||||
42612af9c55c9a33c131b1761c4cde0a97e41cc48f78c118f5249ae5cf87ec46 plant-09.bin
|
||||
0aabce9d5e76b23626b5b04c3d35731568d8cc965e87006d4458e505d14c83dc plant-10.bin
|
||||
ded0a457507c935a86d14abcb603b81747139fe107657f7a21ab8f2293747dd6 plant-11.bin
|
||||
5ac05274d9f4cd0daebc62a02df0fc76045fb722a309a702a6a7874ec7a34ec5 plant-12.bin
|
||||
6593d15aa3e580970660fc406cbfb7f4116499ba6d0f0495d6dab88c73238ce8 plant-13.bin
|
||||
b1810d59dc548600c23f49e8ec56fc121f6d7ba67a4acaea4db1380f85cd70c8 plant-14.bin
|
||||
8197f84a48f001fc1b056e96ca9bd7302d7bee232b449903486db7406e30203d plant-15.bin
|
||||
32436352885d939d451d72cecf358558d2696cf25f5685d28686ce87029121ed plant-16.bin
|
||||
b2556174851fff1c3c21cb8c28a14887d3459e33f96f894aa85882a402da83ab plant-17.bin
|
||||
dd0ceedb353679e6d61876c4898477f29362e3d1fb3707ff67e78921ab03aac4 plant-18.bin
|
||||
6c842b657602840f3e866971007feb00a16378838bebb37f04d4dcf826df6247 plant-19.bin
|
||||
c088602f92943929018670b76607a77f621ab1c1997c022577a371834a4d4d45 plant-20.bin
|
||||
@@ -1,3 +1,10 @@
|
||||
## 2026-10-14 (night) — plugcut: a real power cut on the HP, with three ways back on
|
||||
|
||||
- New `scripts/bench/plugcut.py` + `test_plugcut.py` (12 tests): refuses any plug but `hp` (N100 only with
|
||||
`--allow-n100`), without `--i-mean-a-power-cut`, over 60 s without `--long`, over 3600 s. The relay off carries the
|
||||
plug countdown (DP 9) in the same command; a detached watchdog is armed first; `finally:` re-arms. Red-proofed: each
|
||||
of nine guards removed in turn, a test failed each. `plugswitch.py` is unchanged.
|
||||
|
||||
## 2026-10-13 (night) — site_gates: the machine estimator moves from UNLISTED to TWINS (R-997)
|
||||
|
||||
- `site_gates.py`: the `gepigeny`/`en/sizing` pair is a normal twin; `UNLISTED` is empty and gate 25 stays for the next
|
||||
|
||||
@@ -53,3 +53,16 @@ Same tools, `--plug hp` (config `~/.config/felhom-bench/plug-hp.json`, the plug
|
||||
the HP at `192.168.0.104`). `plugswitch.py off --plug hp` refuses until the HP's switched-off figure (`standby_w`) is
|
||||
measured. The wizard reads both plugs from one Tuya account; the credentials are `TUYA_DEVICE_ID_N100` and
|
||||
`TUYA_DEVICE_ID_HP` (renamed from `TUYA_DEVICE_ID` by the operator).
|
||||
|
||||
## plugcut.py — a real power cut, on purpose (2026-10-13 night)
|
||||
|
||||
`plugswitch.py off` stays „not a power-cut button". `plugcut.py` is the separate tool that cuts a running machine:
|
||||
|
||||
~/.venvs/plugmeter/bin/python scripts/bench/plugcut.py --plug hp --off-seconds 10 --i-mean-a-power-cut --log DIR
|
||||
|
||||
- Only the plug `hp` (the N100's only with `--allow-n100`); only with `--i-mean-a-power-cut`; 1–60 s, up to 3600 s
|
||||
only with `--long`.
|
||||
- Three ways back on: the plug's own countdown (data point 9, sent in the same command as the off, then read back —
|
||||
not shown running → on at once); a detached watchdog process started before the off (on after off-seconds + 15 s,
|
||||
survives the tool being killed); `finally:` in the tool.
|
||||
- One line per action to stdout and `DIR/plugcut.log`. Pinned by `test_plugcut.py` (12 tests, each guard red-proofed).
|
||||
|
||||
@@ -0,0 +1,153 @@
|
||||
#!/usr/bin/env python3
|
||||
"""plugcut.py — a REAL power cut on a bench machine, with three ways back on.
|
||||
|
||||
~/.venvs/plugmeter/bin/python scripts/bench/plugcut.py --plug hp --off-seconds 10 --i-mean-a-power-cut \
|
||||
[--long] [--log DIR]
|
||||
|
||||
This is NOT plugswitch.py. `plugswitch.py off` stays „not a power-cut button" (it refuses a running machine).
|
||||
This tool cuts a running machine on purpose, so it is fenced:
|
||||
|
||||
- only the plug `hp` (the N100's plug only with --allow-n100, the operator's „N100: B"; nothing else exists);
|
||||
- only with --i-mean-a-power-cut;
|
||||
- --off-seconds 1..60; up to 3600 only with --long.
|
||||
|
||||
Three ways the power comes back, so a dead DooPlex or a killed tool cannot leave a machine without power:
|
||||
1. THE PLUG'S OWN COUNTDOWN (data point 9, countdown_1): sent in the SAME command as the relay off, then read
|
||||
back. If the read-back does not show the countdown running, the relay is switched on at once.
|
||||
2. A WATCHDOG PROCESS, started (detached, own session) BEFORE the off: it sleeps off-seconds + 15 s and then
|
||||
switches the relay on. It survives this process being killed.
|
||||
3. `finally:` in this process: the relay is switched on (and read back) whatever happened after the off.
|
||||
|
||||
One line per action (UTC, plug, relay, countdown) to stdout and, with --log DIR, to DIR/plugcut.log.
|
||||
The key and the device id are never printed. Pinned by scripts/bench/test_plugcut.py.
|
||||
"""
|
||||
import argparse, os, subprocess, sys, time
|
||||
from datetime import datetime, timezone
|
||||
|
||||
sys.path.insert(0, os.path.dirname(os.path.abspath(__file__)))
|
||||
from plugswitch import load, device # noqa: E402 (same plug files, same connection settings)
|
||||
|
||||
MAX_S = 60
|
||||
MAX_LONG_S = 3600
|
||||
WATCHDOG_EXTRA_S = 15
|
||||
LOG_DIR = None
|
||||
|
||||
|
||||
def say(plug, msg):
|
||||
line = f'{datetime.now(timezone.utc).strftime("%Y-%m-%dT%H:%M:%S.%f")[:-3]}Z {plug} {msg}'
|
||||
print(line, flush=True)
|
||||
if LOG_DIR:
|
||||
with open(os.path.join(LOG_DIR, 'plugcut.log'), 'a') as f:
|
||||
f.write(line + '\n')
|
||||
|
||||
|
||||
def refuse_reason(a):
|
||||
"""None when allowed, else why not. Pure: tested without a plug."""
|
||||
if a.plug not in ('hp', 'n100'):
|
||||
return f'unknown plug {a.plug!r}'
|
||||
if a.plug == 'n100' and not a.allow_n100:
|
||||
return 'the N100 is not cut unless the operator said „N100: B" (--allow-n100)'
|
||||
if not a.i_mean_a_power_cut:
|
||||
return 'this cuts a running machine: add --i-mean-a-power-cut'
|
||||
if a.off_seconds < 1:
|
||||
return 'off-seconds must be at least 1'
|
||||
limit = MAX_LONG_S if a.long else MAX_S
|
||||
if a.off_seconds > limit:
|
||||
return f'off-seconds {a.off_seconds} is over {limit}' + ('' if a.long else ' (longer needs --long)')
|
||||
return None
|
||||
|
||||
|
||||
def relay(dev):
|
||||
s = dev.status()
|
||||
d = s.get('dps', {}) if isinstance(s, dict) else {}
|
||||
return d.get('1'), d.get('9')
|
||||
|
||||
|
||||
def start_watchdog(plug, after_s):
|
||||
"""Detached process that switches the relay on after `after_s` s. Returns its pid."""
|
||||
args = [sys.executable, os.path.abspath(__file__), '--watchdog', str(after_s), '--plug', plug]
|
||||
if LOG_DIR:
|
||||
args += ['--log', LOG_DIR]
|
||||
p = subprocess.Popen(args, stdin=subprocess.DEVNULL, stdout=subprocess.DEVNULL, stderr=subprocess.DEVNULL,
|
||||
start_new_session=True)
|
||||
return p.pid
|
||||
|
||||
|
||||
def turn_on_verified(dev, plug, who, tries=5):
|
||||
for i in range(tries):
|
||||
try:
|
||||
dev.turn_on()
|
||||
on, cd = relay(dev)
|
||||
say(plug, f'{who}: relay={"on" if on else "off?"} countdown={cd}')
|
||||
if on:
|
||||
return True
|
||||
except Exception as e: # a slow plug read is late, not lost — try again
|
||||
say(plug, f'{who}: try {i + 1} failed ({type(e).__name__})')
|
||||
time.sleep(2)
|
||||
return False
|
||||
|
||||
|
||||
def cut(dev, plug, off_s, watchdog=start_watchdog, sleep=time.sleep, now=time.monotonic):
|
||||
"""The cut. Returns 0 when the relay is on again at the end."""
|
||||
pid = watchdog(plug, off_s + WATCHDOG_EXTRA_S)
|
||||
say(plug, f'watchdog armed (pid {pid}, relay on after {off_s + WATCHDOG_EXTRA_S} s at the latest)')
|
||||
try:
|
||||
dev.set_multiple_values({'1': False, '9': int(off_s)})
|
||||
say(plug, f'CUT: relay off + countdown {off_s} s sent in one command')
|
||||
on, cd = relay(dev)
|
||||
say(plug, f'read back: relay={"on" if on else "off"} countdown={cd}')
|
||||
if on is not False or not cd:
|
||||
say(plug, 'countdown NOT shown running — switching on now (fail-safe)')
|
||||
return 0 if turn_on_verified(dev, plug, 'fail-safe') else 1
|
||||
t0 = now()
|
||||
sleep(off_s)
|
||||
while now() - t0 < off_s + 10:
|
||||
try:
|
||||
on, cd = relay(dev)
|
||||
except Exception:
|
||||
on = None
|
||||
if on:
|
||||
say(plug, f'BACK: relay on by the plug countdown, +{now() - t0:.1f} s after the cut')
|
||||
return 0
|
||||
sleep(1)
|
||||
say(plug, 'the countdown did not switch the relay on within off-seconds + 10 s')
|
||||
return 1
|
||||
finally:
|
||||
try:
|
||||
on, cd = relay(dev)
|
||||
except Exception:
|
||||
on = None
|
||||
if not on:
|
||||
turn_on_verified(dev, plug, 'finally re-arm')
|
||||
|
||||
|
||||
def main(argv):
|
||||
global LOG_DIR
|
||||
ap = argparse.ArgumentParser(description=__doc__.split('\n')[0])
|
||||
ap.add_argument('--plug', default='hp')
|
||||
ap.add_argument('--off-seconds', type=int, default=0)
|
||||
ap.add_argument('--i-mean-a-power-cut', action='store_true')
|
||||
ap.add_argument('--long', action='store_true')
|
||||
ap.add_argument('--allow-n100', action='store_true')
|
||||
ap.add_argument('--log')
|
||||
ap.add_argument('--watchdog', type=int, help=argparse.SUPPRESS)
|
||||
a = ap.parse_args(argv)
|
||||
LOG_DIR = a.log
|
||||
if a.watchdog is not None: # the detached watchdog: sleep, then make sure the relay is on
|
||||
time.sleep(a.watchdog)
|
||||
dev = device(load(a.plug))
|
||||
on, _ = relay(dev)
|
||||
if on:
|
||||
say(a.plug, 'watchdog: relay already on — nothing to do')
|
||||
return 0
|
||||
return 0 if turn_on_verified(dev, a.plug, 'WATCHDOG') else 1
|
||||
why = refuse_reason(a)
|
||||
if why:
|
||||
print(f'REFUSED: {why}', file=sys.stderr)
|
||||
return 2
|
||||
dev = device(load(a.plug))
|
||||
return cut(dev, a.plug, a.off_seconds)
|
||||
|
||||
|
||||
if __name__ == '__main__':
|
||||
sys.exit(main(sys.argv[1:]))
|
||||
@@ -0,0 +1,117 @@
|
||||
#!/usr/bin/env python3
|
||||
"""Pins plugcut.py: its refusals, the countdown sent WITH the off, the watchdog armed BEFORE the off,
|
||||
the fail-safe when the countdown does not show, and the `finally:` re-arm. A fake plug, no network."""
|
||||
import argparse, os, sys, unittest
|
||||
sys.path.insert(0, os.path.dirname(os.path.abspath(__file__)))
|
||||
import plugcut # noqa: E402
|
||||
|
||||
|
||||
def args(**kw):
|
||||
d = dict(plug='hp', off_seconds=10, i_mean_a_power_cut=True, long=False, allow_n100=False)
|
||||
d.update(kw)
|
||||
return argparse.Namespace(**d)
|
||||
|
||||
|
||||
class FakePlug:
|
||||
"""Records every command. `countdown_works`: the plug turns itself on when the countdown ends."""
|
||||
def __init__(self, countdown_works=True, show_countdown=True, fail_after_off=False):
|
||||
self.on, self.cd, self.log = True, 0, []
|
||||
self.countdown_works, self.show_countdown, self.fail_after_off = countdown_works, show_countdown, fail_after_off
|
||||
self.clock = 0.0
|
||||
|
||||
def set_multiple_values(self, v):
|
||||
self.log.append(('set', dict(v)))
|
||||
if '1' in v:
|
||||
self.on = v['1']
|
||||
if '9' in v and self.show_countdown:
|
||||
self.cd = v['9']
|
||||
|
||||
def turn_on(self):
|
||||
self.log.append(('on',))
|
||||
self.on, self.cd = True, 0
|
||||
|
||||
def status(self):
|
||||
if self.fail_after_off and not self.on and any(e[0] == 'status' for e in self.log):
|
||||
self.log.append(('status',))
|
||||
raise RuntimeError('plug gone')
|
||||
self.log.append(('status',))
|
||||
return {'dps': {'1': self.on, '9': self.cd}}
|
||||
|
||||
def tick(self, s):
|
||||
self.clock += s
|
||||
if self.countdown_works and not self.on and self.cd and self.clock >= self.cd:
|
||||
self.on, self.cd = True, 0
|
||||
|
||||
|
||||
class Refusals(unittest.TestCase):
|
||||
def test_allowed(self):
|
||||
self.assertIsNone(plugcut.refuse_reason(args()))
|
||||
|
||||
def test_without_the_long_flag(self):
|
||||
self.assertIn('--i-mean-a-power-cut', plugcut.refuse_reason(args(i_mean_a_power_cut=False)))
|
||||
|
||||
def test_n100_without_operator_word(self):
|
||||
self.assertIn('N100', plugcut.refuse_reason(args(plug='n100')))
|
||||
self.assertIsNone(plugcut.refuse_reason(args(plug='n100', allow_n100=True)))
|
||||
|
||||
def test_unknown_plug(self):
|
||||
self.assertIn('unknown', plugcut.refuse_reason(args(plug='dooplex')))
|
||||
|
||||
def test_over_60_needs_long(self):
|
||||
self.assertIn('--long', plugcut.refuse_reason(args(off_seconds=61)))
|
||||
self.assertIsNone(plugcut.refuse_reason(args(off_seconds=3000, long=True)))
|
||||
|
||||
def test_long_capped_at_3600(self):
|
||||
self.assertIsNotNone(plugcut.refuse_reason(args(off_seconds=3601, long=True)))
|
||||
|
||||
def test_zero_seconds(self):
|
||||
self.assertIsNotNone(plugcut.refuse_reason(args(off_seconds=0)))
|
||||
|
||||
|
||||
class Cut(unittest.TestCase):
|
||||
def run_cut(self, plug, off_s=10):
|
||||
order = []
|
||||
def watchdog(p, after):
|
||||
order.append(('watchdog', after, len(plug.log)))
|
||||
return 4242
|
||||
rc = plugcut.cut(plug, 'hp', off_s, watchdog=watchdog, sleep=plug.tick, now=lambda: plug.clock)
|
||||
return rc, order
|
||||
|
||||
def test_countdown_sent_with_the_off(self):
|
||||
p = FakePlug()
|
||||
rc, _ = self.run_cut(p)
|
||||
first_off = next(e for e in p.log if e[0] == 'set' and e[1].get('1') is False)
|
||||
self.assertEqual(first_off[1].get('9'), 10, 'the off must carry the countdown in the same command')
|
||||
self.assertEqual(rc, 0)
|
||||
self.assertTrue(p.on)
|
||||
|
||||
def test_watchdog_armed_before_the_off(self):
|
||||
p = FakePlug()
|
||||
_, order = self.run_cut(p)
|
||||
self.assertEqual(order[0][2], 0, 'the watchdog must start before any command reaches the plug')
|
||||
self.assertEqual(order[0][1], 10 + plugcut.WATCHDOG_EXTRA_S)
|
||||
|
||||
def test_failsafe_when_countdown_not_shown(self):
|
||||
p = FakePlug(show_countdown=False)
|
||||
rc, _ = self.run_cut(p)
|
||||
self.assertTrue(p.on)
|
||||
self.assertIn(('on',), p.log)
|
||||
self.assertEqual(rc, 0)
|
||||
|
||||
def test_finally_rearms_when_countdown_never_fires(self):
|
||||
p = FakePlug(countdown_works=False)
|
||||
rc, _ = self.run_cut(p)
|
||||
self.assertEqual(rc, 1, 'a countdown that did not fire is a failed cut')
|
||||
self.assertTrue(p.on, 'finally: must switch the relay back on')
|
||||
|
||||
def test_finally_rearms_after_an_exception(self):
|
||||
p = FakePlug(fail_after_off=True)
|
||||
try:
|
||||
self.run_cut(p)
|
||||
except Exception:
|
||||
pass
|
||||
self.assertTrue(p.on, 'finally: must switch the relay back on after an error')
|
||||
|
||||
|
||||
if __name__ == '__main__':
|
||||
unittest.main()
|
||||
Reference in New Issue
Block a user