# REPORT — agent v0.85.0: the boot/recovery plane + appliance self-heal (CAMPAIGN-3 Task A)
**Date:** 2026-07-12 · **Baselines:** agent v0.84.0 (`bec4bac`) → **v0.85.0**; felhom.eu post-`f97f7803`.
**Source of truth:** `felhom.eu/documentation/audits/CAMPAIGN-3-2026-07-11.md`.
**Scope:** F12 (CRITICAL), F11/F10/F9 (HIGH/CRITICAL), F2/F1 (LOW), the guest-hook rc255 belt, and the
operator-mandated appliance-mode node self-heal. Controller untouched (MinAgent unchanged). Green gate
(`go build ./... && go vet ./... && go test ./...`) PASS on the build server.
## What shipped
- **F12 (CRITICAL) — boot ordering cycle.** Both rendered units drop `After=/Wants=network-online.target`
(`.mount` keeps `_netdev`; `.automount` gets no network relation). `MigrateNetworkUnits` — a general
template-drift reconcile (SHA-256 content compare vs a fresh render of the reconstructed spec;
rewrite + one batched `daemon-reload`; idempotent) — repairs ALREADY-INSTALLED units at startup and
at the head of `EnsureNetworkMount`.
- **F11 — read the right unit** (`netReassertClassify`): decision by host `/proc/mounts` fstype only,
never the automount's own state. **Matrix-corrected:** a rebooted guest inherits neither an idle
trigger NOR an active mount, so the callers re-arm reactively when a running guest is found blind
(`RearmNetworkAutomount` after a failed visibility check).
- **F10 — re-arm for real:** a failed/start-limited unit is `reset-failed` before `enable --now`
(unprivileged `systemctl is-failed` seam + new sudoers verb).
- **F9 — say what you did:** enumerate by marker-owned unit files; one INFO verdict per share.
- **F2/F1 — zero residue:** `RemoveNetworkMount` (and every verify-fail rollback via it) reset-failed's
the pair and `rmdir`s the mountpoint (rmdir-only fail-safe; never `rm -rf`).
- **Hook can never take a guest down:** `runHookPhase` — per-phase recover + hard timeout, always
returns; the installed wrapper snippet no longer `exec`s (`… || true; exit 0`).
- **Appliance self-heal (`internal/selfheal`):** one heal — host networking recovery, gated on
`deployment_mode:"appliance"`; byo runs the check + WARNs, remedy unreachable. Config
`deployment_mode` (+`FELHOM_AGENT_DEPLOYMENT_MODE`, `IsAppliance()` fail-safe-to-byo).
## Sudoers — three grants added (LOUD, per the no-widening rule)
Shipped with the binary; capability manifest updated (probed live: 62/62, 0 degraded):
1. **`systemctl reset-failed -- mnt-felhom*`** (FELHOM_NETMOUNT) — F10: no platform path could re-arm a
start-limited automount. reset-failed only clears a failed latch; it cannot start/stop anything.
2. **`rmdir /mnt/felhom-drives/*`** (FELHOM_NETMOUNT) — F1: removed-share mountpoint cleanup. rmdir
refuses a non-empty dir (fail-safe; unexpected data is preserved, never `rm -rf`'d).
3. **`systemctl start networking.service`** (new FELHOM_SELFHEAL alias) — F12-class appliance self-heal.
Fixed unit, no glob; the grant alone cannot harm; the remedy is ALSO code-gated on appliance mode.
## Tests + red-proofs (all green)
- Render: no network-online in either unit, `_netdev` present (companion: re-adding the line fails).
- Reconcile: drifted (legacy) unit rewritten once + batched daemon-reload; idempotent (0 rewrites 2nd
pass); spec round-trip exact; foreign units ignored.
- Reassert: fstype table with the automount-state-ignored red-proof; reset-failed+rearm verdict;
per-unit verdict count (F9); re-arm-on-guest-blind (F11 matrix-correction); byo-blind non-fatal.
- Hook rc-0 under panic + timeout (Part 4); zero-residue (reset-failed + rmdir, never rm -rf).
- Self-heal state machine; **byo-never-invokes red-proof** (byo + unhealthy → zero privileged
invocations); absent field ⇒ byo.
## Live MATRIX (demo felhom-pve, agent 0.85.0 + deployment_mode=appliance)
Deploy verified: startup migrated the installed nas-media units (0 network-online lines); no interim
drop-in existed to remove (the campaign recovery used reset-failed+restart, not a drop-in).
| # | Row | Result |
|---|-----|--------|
| 1 | guest reboot × idle share ×2 | **PASS** — zero-touch: reassert re-armed, guest sees NAS, write-through OK, 4 NAS apps auto-started |
| 2 | guest reboot × active share | **F13 (new finding)** — active nfs4 under mp8 can fail PVE's rbind (rc255, idmap); NAS-down-at-boot → apps `Created` (deferred fix-3). Independent of the felhom hook (rc0). |
| 3 | F10 manufacture → agent restart | **PASS** — sweep `reset-failed` both units (loud WARN) + re-armed (verdict `reset-failed+rearmed`); the campaign's silent no-op is gone |
| 4 | F10 state → guest reboot (hook path) | **PASS** — guest STARTS (rc0); F11 matrix-correction healed the blind guest live ("re-arming … visible after re-arm (healed)") |
| 5 | 🛑 host reboot ×2 | **PASS**`grep -c "ordering cycle"` == **0 on BOTH boots**, networking up, automount armed, guest + 8 apps healthy. **F12 coin flip is dead.** |
| 6 | 🛑 stop networking (appliance) | **PASS** — watchdog WARNed `active=false`, fired the privileged start, recovered on attempt 1 (~11 s). BYO live variant NOT run (red-proof only). |
| 7 | refused add + remove cycles ×3 | **PASS** — zero residue (0 units/dirs/failed/creds; campaign left 10 dirs); registry clean |
## NOT live-validated / standing items
- **Row 6 byo variant** — not run live (would leave the box dark); byo is red-proof-tested only.
- **F13 (NEW, HIGH)** — active-nfs-under-mp8 rc255 + NAS-down-at-boot apps-`Created`. Deferred (needs a
pre-start idle-unmount design for multi-guest hosts, or an idmapped nfs mount + fix-3 alerting).
- **Peti** runs agent 0.81 — unaffected by this train until his rollout; if his box has a NAS share he
carries the F12 coin flip until then (interim drop-in recipe below).
- Task B/C/D findings (F7/F6/F5, F8/F4, ring/alerting) remain queued.
- **Publish train:** 0.85 is customer-critical (F12 affects any customer with a NAS share) — prioritize.
## Box state at wrap
agent 0.85.0 / deployment_mode=appliance; nas-media clean (no ordering cycle) + active; 0 failed felhom
units; 0 leftover mountpoint dirs (19 pre-fix campaign leftovers rmdir'd); guest 9201 + all 10
containers healthy with NAS data intact.
### Interim F12 mitigation for a not-yet-upgraded host
A systemd drop-in on each installed `mnt-felhom…-<name>.automount` with empty `After=`/`Wants=`
overrides + `daemon-reload` strips the ordering until the 0.85 agent migrates the unit at startup.