Files
felhom.eu/documentation/audits/catalog-sweep-2026-10-24/n8n/run-drill-pre/walk.log
T
admin 67053335d1
gates / gates (push) Successful in 13m17s
Catalog sweep 2026-10-24: all 65 catalog apps on a fresh box (52 work, 10 with a problem, 0 broken); register 208 -> 217 (R-1269..R-1277 opened; notes on R-739, R-1267); STATUS + D46; map B1 re-checked; evidence
Every catalog app installed, used, backed up, removed keeping data, reinstalled, restored and removed with data on a
fresh box from the public ISO (demo-hp VM 9360, Tester4), endpoint-level. Worst: a reinstall's capture rewrites the
kept unit so its restore breaks the app (R-1269, P2), the restore still reports success (R-1270, P2), and „use my kept
data" loaded another box's future-dated database (R-1271, P2). Drill catalog fixes for the morning list (n8n usage
data; OpenGist 256M, proven by a cgroup probe). VM 9360 and LXC 9361 destroyed; hub host Tester4-aa9466 left for the
operator. REPORT-catalog-sweep-2026-10-24.md.
2026-10-25 00:13:05 +02:00

16 lines
1.5 KiB
Plaintext
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
18:37:24Z [1] deploy -> 202 {'ok': True, 'message': 'Telepítés elindítva – az állapot a kártyán követhető'}
18:39:34Z [1] deployed, controller state=running, pinned={'n8n': 'n8nio/n8n:2.42.1'}
18:39:34Z gate: auto is gated — passed as the household (cookie set)
18:39:34Z [1] installed: deployed 131 s, front door 131 s
18:39:35Z n8n: /rest/owner/setup http=200
18:39:35Z n8n: READBACK UNUSABLE — a wrong password authenticated
18:40:02Z [4] Mentés most -> 200 {'ok': True, 'message': 'Mentés elindítva'}
18:40:12Z [6] POST /backup/restore -> HTTP/2 302 ['location: /backups/restore?flash=flash.restore.started']
18:40:32Z n8n: login as the seeded owner http=401 ok=False
18:41:07Z [5] stop 200, remove KEEPING data -> 200 {'ok': True, 'data': {'removed': 'n8n', 'volumes_removed': ['n8n_n8n_data'], 'hdd_paths_removed': [], 'hdd_paths_preserved': [], 'userdata_kept': [], 'verified': True}, 'message': 'Stack n8n removed'}
18:43:38Z n8n: READBACK UNUSABLE — a wrong password authenticated
18:43:38Z [6] POST /backup/restore -> HTTP/2 302 ['location: /backups/restore?flash=flash.restore.started']
18:44:03Z n8n: login as the seeded owner http=401 ok=False
18:44:43Z [7] stop 200, remove with data -> 200 {'ok': True, 'data': {'removed': 'n8n', 'volumes_removed': ['n8n_n8n_data'], 'hdd_paths_removed': [], 'hdd_paths_preserved': [], 'hdd_note': 'Az alkalmazás nem tárolt saját adatot külső meghajtón, így
18:44:51Z == n8n done in 448 s