970616b72b
gates / gates (push) Failing after 11m41s
The catalogue side is app-catalog-felhom.eu b7f0f7c. Here: the evidence, the website, the register and the operator's view. Website - Two cards in the Otthon & Eletmod / Home & Lifestyle section of BOTH apps pages, with assets: grocy-logo.svg is grocy's own icon with its single fill made white like the other logos, lubelogger-logo.png is the app's own icon with its dark background dropped and the mark made white (the rule SparkyFitness's PNG follows), and six screenshots of each app's own UI with a household's own data, taken headless on the bench from the published template. - The app count moved 56 -> 58 in 15 places per language set, both languages, and the open-source tile 49 -> 51. Checked by asking the same patterns for the new number afterwards. marketing/facebook/COPY.md still says 56 and is NOT changed: the post it carries is already scheduled. Evidence - documentation/audits/new-apps-2026-10-10/ — FIT.md (checklist group 0 for all three, with the Hungarian-UI column), the bench and box transcripts, the memory samples, the screenshots and the gate runs. Register: 137 -> 139 rows, 2 opened, 0 closed. - R-926 after a remove-keeping-backups and restore, nobody has checked what the app page shows for an after_install app's generated password. Measured here: LubeLogger is safe (its login is derived from the environment at every start, the new password signs in, the data is back); grocy's install password still signs in from the restored database but the deployed environment no longer carries ADMIN_PASSWORD at all. Seven apps are in the class. - R-927 Monica, stopped at checklist 0.2 with the measurements, waiting on the operator. Gate scripts: the same console trap in nineteen of them and in repo_gates.py itself, where it ABORTED THE WHOLE RUNNER at the first gate — printing a non-ASCII character on this workstation's cp1250 console raised UnicodeEncodeError before the gate had decided anything, and reuse_refs_check.py died while printing a NOTE. All now reconfigure their own streams. Red-proof that the remaining script-test failures are not mine: test_due_checks_gate.py fails the same 5 of 42 with the change reverted.
9 lines
1.5 KiB
Plaintext
9 lines
1.5 KiB
Plaintext
5.1 (box) grocy [81b6c2d60086] 189 samples: peak anon 45.7 MiB = 11.9 % of the limit; peak swap 0 B; oom_kill 0
|
|
2.6 remove (remove_hdd_data=True) -> 200 {'ok': True, 'data': {'removed': 'grocy', 'volumes_removed': ['grocy_grocy_config'], 'hdd_paths_removed': [], 'hdd_paths_preserved': [], 'hdd_note': 'Az alkalmazás nem tárolt saját adatot külső meghajtón, így ott nem volt mit törölni.', 'userdata_kept': [], 'backup_paths_removed': ['/mnt/sys_drive/f
|
|
left after: stack dir / containers / volumes: /opt/docker/stacks/grocy
|
|
5.1 (box) grocy [7005b3a4c2b2] 135 samples: peak anon 86.6 MiB = 22.5 % of the limit; peak swap 0 B; oom_kill 0
|
|
2.6 remove (remove_hdd_data=True) -> 200 {'ok': True, 'data': {'removed': 'grocy', 'volumes_removed': ['grocy_grocy_config'], 'hdd_paths_removed': [], 'hdd_paths_preserved': [], 'hdd_note': 'Az alkalmazás nem tárolt saját adatot külső meghajtón, így ott nem volt mit törölni.', 'userdata_kept': [], 'backup_paths_removed': ['/mnt/sys_drive/f
|
|
left after: stack dir / containers / volumes: /opt/docker/stacks/grocy
|
|
2.6 remove (remove_hdd_data=True) -> 200 {'ok': True, 'data': {'removed': 'grocy', 'volumes_removed': ['grocy_grocy_config'], 'hdd_paths_removed': [], 'hdd_paths_preserved': [], 'hdd_note': 'Az alkalmazás nem tárolt saját adatot külső meghajtón, így ott nem volt mit törölni.', 'userdata_kept': [], 'backup_paths_removed': ['/mnt/sys_drive/f
|
|
left after: stack dir / containers / volumes: /opt/docker/stacks/grocy
|