Phase 0 sized C9-F1 properly before anything was designed: 43 of the 53 catalog apps have NO subtree the Tier-2 restore can read (not 2), 9 are covered only for their file legs and never their database or volumes, 1 is stateless. The asymmetry is Tier-2's alone — Tier-1 and offsite both restore the unit and replay volume dumps, so BookStack always had a working restore and only this button lied. Shipped: the restore refuses BEFORE stopping the app and names the action that does work; a run that proceeds claims only what it EXAMINED and discloses that the database and volumes are not covered. C9-F2 alarms after a 5-minute sustained-restarting threshold, set above the 120s deploy timeout, Mealie's 60s start_period and R-97b's 180s grace; StateRestarting is deliberately NOT added to IsDownState. Live: silent through ten 30s samples then app_start_failed at 5m25s, heartbeat now reads "1 currently down" where Campaign 9 recorded 0; a real deploy stayed silent; bookstack refused with its uptime unbroken; paperless re-restored 43/43 byte-identical, 16/16 docs clean. Filed, not fixed: C9-F1b (route to the Tier-1 restore — its own task because it puts a destructive operation behind a non-destructive button) and C9-F4 (nothing reads the Tier-2 copy's recovery-unit/ mirror, so the second local copy that exists for drive loss is unreachable by any customer action — potentially larger than C9-F1).