gates / gates (push) Successful in 6m35s
plugswitch.py refuses 'off' unless 20 s of readings show the N100 is already off (standby + 1 W, no ping); 7 tests, each check red-proofed. By hand: guest shutdown 12 s, host off, 0.0 W; the hub stayed silent and 'ONLINE' for 18 min; plug off/on did not start the N100, its power button did (dashboard in 42 s). Wall figures into SIZING.md 4 and sizing.json power (8.5 / 20.7 / 0.0 W).
16 lines
615 B
Plaintext
16 lines
615 B
Plaintext
up after 5s (200)
|
|
admin-sign-up 201
|
|
token length 39
|
|
@1791909148 action_start upload
|
|
@1791909228 upload_done ok=200 bad=0
|
|
t=5s jobs pending=363
|
|
t=65s jobs pending=407
|
|
t=125s jobs pending=221
|
|
t=185s jobs pending=195
|
|
t=245s jobs pending=169
|
|
t=305s jobs pending=64
|
|
t=365s jobs pending=0
|
|
@1791909590 action_end jobs-idle
|
|
{"photos":200,"videos":0,"usage":833025787,"usagePhotos":833025787,"usageVideos":0,"usageByUser":[{"userId":"2738a268-8f74-4b76-9ad1-d4fb705c4116","userName":"Bench","photos":200,"videos":0,"usage":833025787,"usagePhotos":833025787,"usageVideos":0,"quotaSizeInBytes":null}]}
|
|
"total":0
|