Full ISO/PAIRING run on a fresh nested box. Agent 0.114.0 came from the Day-0 manifest -- the SHIPPED binary -- so C5 tested the real artifact. Controller 0.186.0 hand-deployed after install per the §3.1 ruling; the vouched golden bakes 0.185.1, so C3/C4 prove the code not the shipped golden, and that lag is filed against R-115 rather than a new ID. R-113 PROVEN: detach 18:43:50, gate fired 18:43:54 -- four seconds, where E-2d measured zero over 4.5 minutes -- and SetDisconnected was reached. It fired on exactly the shape that defeated it: raw /mnt/mentes NOT mounted while the bind /mnt/felhom-drives/mentes still read /dev/sdb[/felhom-data]. R-114 PROVEN: with the target absent the page rendered the absent copy, the system-disk copy 0 and the offer block 0. Both of E-2d's falsehoods are gone. R-112 PROVEN: the banner reached a customer's page for the first time. Healthy renders nothing, proven POSITIVELY -- idle delta 0 /backup/tiers calls, page load delta +1, single caller, so the seam ran and chose silence. C5 FAILED on a fourth, separate defect. The alarm fires but as the GENERIC storage_disconnected, while the recovery is the SPECIFIC backup_target_restored -- a pair an operator cannot match, which is what notifyDriveReturned's own comment forbids. backup_target_absent count 0 across the run. Root cause: the drive is TWO /disks rows and BackupTarget and GuestPath sit on different ones; absent they separate, on return they rejoin. v0.184.1 fixed the keying, not this. Only reachable because R-113 made the gate fire at all. Filed as R-116. Mirror + over-correction guard PASS: non-target drive -> storage_disconnected, backup_target_absent 0; both drives present -> 0 ABSENT lines and the target stayed healthy. Caveat recorded: the mirror passes trivially because the target also produced the generic event. E-2 and E-2d CLOSED as partially proven with R-116 the one named open leg, per the runbook's §9 rule decided in advance rather than mid-run. Capability map NOT touched: it has no E-2 rows at all, so nothing could move to PROVEN-LIVE. Creating them is a design act, not a validation act. Teardown clean: pvesm status after == before (local-lvm 38.78%), guest 9201 and drill-r50 untouched. Customer delete attempted and correctly refused while the host still reads ONLINE; command recorded for once it ages to DOWN.
11 KiB
SESSION-C-2026-07-29 — R-113, R-114, R-112 proven on a real box; C5 fails on a new defect
Run: RUNBOOK-session-c-2026-07-29.md, executed by CC on DooPlex, 2026-07-29.
Session C of three. A → R-113 (agent v0.114.0) · B → R-114 + R-112 (controller v0.186.0) · C → this.
| Claim | Fix | Verdict |
|---|---|---|
| C4 — the offer appears and moves the target when accepted | R-112 | ✅ PASS |
| C3 — with the target absent the customer is told the drive is missing, and offered nothing | R-114 | ✅ PASS |
C5 — drive loss produces backup_target_absent (error) and backup_target_restored (info) |
R-113 | ❌ FAIL — the alarm fires, but as the generic event; the recovery is the specific one. Unmatched pair → R-116 |
All three fixes are proven to work. R-113's gate fires, R-114's message is correct, R-112's banner reaches the customer. C5 fails on a fourth, separate defect that only became reachable because R-113 made the gate fire at all — it could not have been seen before.
1. Baselines, and what the drill box actually ran
| Artifact | Vouched / used | How it got there |
|---|---|---|
| agent | 0.114.0 | from the Day-0 manifest — Artifact manifest served for sess-c (agent=0.114.0 golden=0.185.1). C5 therefore tested the shipped binary, closing R-115 observation 1 for R-113 |
| golden | 0.185.1 | vouched; bakes controller 0.185.1 |
| controller | 0.186.0 | hand-deployed after install (§3.1 ruling (a)) via the bootstrap path — 0.185.1 → 0.186.0, Up 21 seconds (healthy) |
| hub | 0.81.0 | unchanged |
| host-install | 1.22.0 | unchanged |
Repos at run time: controller b331f18, agent b58d7bc, felhom.eu af518ba, all clean.
§3.1 ruling — (a), deploy 0.186.0 by hand. A bake is its own session and would have inserted one before any verdict; the install path is already proven by E-2d. Caveat, as required: C3/C4 prove the CODE, not the SHIPPED GOLDEN. The vouched golden lagging a controller release is R-115's shape and is filed there, not as a new ID.
§3.2 cadence — driveGateLoop registered server.go:224, defined intermediary.go:328, ticker
30 s (:339) ⇒ C5 budget 60 s. §3.3 — SCSI hot-detach, volume survives as unused0.
Fence re-measured before and after: local-lvm 38.78 % both times.
2. Timeline (VM 9301 sessionc, nested PVE on demo-hp)
| UTC | Event |
|---|---|
| 18:29 | VM created — one disk, q35/OVMF SB-off, hotplug disk, outside the felhom pool |
| 18:33:47 | registered unclaimed, pairing code 2XT-3PV |
| 18:34:08 | bound to sess-c by CC — no operator STOP (E-2d retired it) |
| 18:34:57 | manifest served: agent 0.114.0, golden 0.185.1 |
| 18:38:03 | controller_started (0.185.1) — install complete, bind→controller in 3 m 55 s |
| ~18:40 | controller 0.186.0 deployed; dashboard claimed with the emailed code |
| 18:43:50 | target drive hot-detached |
| 18:43:54 | gate fired — 4 seconds |
| 18:47:01 | reattached |
| 18:47:24 | gate RETURNED (23 s) |
| 18:50:32 | non-target drive detached (mirror) |
| 18:50:54 | gate fired (22 s) |
3. C4 — PASS (R-112 + the assign flow)
The banner reached a customer's page for the first time. E-2d could only prove the JSON.
Never-configured box, before any second drive:
GET /backups http=200
banner element : 1
never-configured copy : 1 <- "ugyanazon a lemezen van" IS in the HTML
absent copy : 0
offer block : 0 <- correct: no eligible drive registered yet
After attaching a 100 GB disk and bringing it in through the dashboard wizard:
banner element : 1 offer block : 1 data-path="/mnt/felhom-drives/mentes"
Decline path — PROVEN. After registering and not accepting: target still local, no
felhom-backup storage, agent.json local_backup_target = local. Registration confers no role.
Accept: {"assigned":"/mnt/felhom-drives/mentes","restart_required":true}.
The agent did NOT self-restart — ActiveEnterTimestamp 20:35:15 CEST, unchanged at 20:42:20.
In-flight check performed and recorded before restarting: 0 vzdump processes, 0 backup lines in
the agent journal (5 min), 0 running PVE tasks. Wrapper created dir: felhom-backup, path /mnt/mentes, is_mountpoint 1 — the drive's own mountpoint.
After restart, healthy renders nothing — and it is proven POSITIVELY, not by an empty page:
banner element 0 · offer block 0 · degraded copy 0 · absent copy 0
/backup/tiers calls before 6 · after idle 8s 6 (delta 0) · after page load 7 (delta +1)
That call has exactly one caller (resolveBackupTargetState), so the seam ran and chose silence.
4. C3 — PASS (R-114)
With the target drive detached, the customer's page:
banner element : 1
ABSENT copy (correct) : 1 <- "vissza nem csatlakoztatod"
system-disk copy (BAD): 0 <- E-2d saw THIS
offer block (BAD) : 0 <- E-2d offered the VANISHED drive
API: {"degraded":true,"target":"felhom-backup","message":"A rendszermentés meghajtója nem érhető el — amíg vissza nem csatlakoztatod, a teljes rendszermentés nem készül el."}
Both of E-2d's falsehoods are gone.
5. C5 — FAIL, and R-113 is nonetheless PROVEN
R-113 works. This is the headline. E-2d measured zero gate activity over 4½ minutes. Here:
18:43:54 [INFO] [settings] Storage path /mnt/felhom-drives/mentes disconnected=true
18:43:54 [WARN] [gate] drive ABSENT /mnt/felhom-drives/mentes — stopped+blocked 0 app(s): []
4 seconds, and SetDisconnected reached — the flag R-114 and the offer suppression depend on.
And it fired on exactly the shape that defeated it before:
raw /mnt/mentes : NOT mounted <- device-bound, died with the device
bind /mnt/felhom-drives/mentes : /dev/sdb[/felhom-data] <- the stale bind SURVIVED
The bind outlived the device, as always; the gate now sees past it.
What fails is which event is sent.
absent : Event pushed: storage_disconnected (error) <- GENERIC
return : Event pushed: backup_target_restored (info) <- SPECIFIC
C5 required backup_target_absent. It never fired — backup_target_absent count 0 across the run.
Worse than a missing label: the alarm and its recovery are a mismatched pair, which is precisely
what notifyDriveReturned's own comment forbids — "a target that alarmed as backup_target_absent has
to recover as backup_target_restored, not as a generic reconnect the operator cannot match". Here it
is inverted: generic alarm, specific recovery.
Root cause, established at source
notifyDriveAbsent (intermediary.go:635-646) branches on isTarget[path], built by
driveTargetByPath (:602-616) as out[GuestPath] = d.BackupTarget / out[MountPath] = d.BackupTarget.
The gate's a.Path is the guest path.
The drive is represented by two /disks rows, and the flag and the guest path sit on different ones:
| Row | Source | BackupTarget |
GuestPath |
|---|---|---|---|
the felhom-backup storage |
Observe path, felhom-agent/internal/localapi/disks.go:211 (t.Name == primaryTargetID) |
true | set only when role is user-data |
| the registry drive | union path, disks.go:265-267 — never assigns BackupTarget at all |
false | /mnt/felhom-drives/mentes |
While the device is absent the target-flagged row loses the classification that gives it a guest path,
so out["/mnt/felhom-drives/mentes"] is written false by the union row and the specific branch is
skipped. On return the rows rejoin and the specific event fires — which is exactly the asymmetry
observed. v0.184.1 fixed the keying (both keys are mapped); it did not fix the flag being absent from
the row that carries the guest path.
(The precise role-classification step that drops the guest path while absent was not isolated — the two-row split and the observed absent/return asymmetry are the evidence.)
Filed as R-116. Not fixed: a defect found in a validation run is a finding.
6. Mirror scenario + over-correction guard — PASS, with a caveat
A non-target drive (adat, 70 GB, registered but never assigned) detached at 18:50:32:
18:50:54 [WARN] [gate] drive ABSENT /mnt/felhom-drives/adat — stopped+blocked 0 app(s)
18:50:54 [INFO] Event pushed: storage_disconnected (error) — Meghajtó váratlanul leválasztva: Adat meghajto
backup_target_absent count : 0 storage_disconnected count : 1
Over-correction guard — the real risk of R-113 — PASSES. With both drives present the gate produced
0 ABSENT lines, and the target stayed degraded:false with banner element 0 throughout the whole
mirror sequence. R-113's stricter presence did not make a healthy drive read absent.
Caveat, stated rather than glossed: because the target drive also produced the generic event, the mirror passes trivially. It confirms no over-correction; it cannot confirm specific-vs-generic discrimination, because nothing produced the specific event on absence at all.
7. Findings
- R-116 (new) — the absent alarm is generic while the recovery is specific; the pair cannot be matched by an operator. Root cause §5. This defect was unreachable before R-113: the gate never ran, so the branch was never taken. Fixing one bug exposed the next, which is what a validation run is for.
- The stale bind survives a return, still naming a dead device node. After the drive came back as
/dev/sdc,findmnt /mnt/felhom-drives/mentesstill read/dev/sdb[/felhom-data]while the state reporteddegraded:false. E-2d noticed this and did not chase it; it is now confirmed. Whether apps writing through that path reach the live device was not established — worth its own look. - The capability map still has no E-2 / backup-target rows at all, so no row could be moved to PROVEN-LIVE. Creating them is a design act, not a validation act; filed rather than invented (third session in a row this has been noted).
8. Teardown
VM 9301 destroyed --purge, sc-images storage removed, scratch dir removed.
pvesm status after == before (local-lvm 38.78 %, felhom-backup 931059224 KiB available).
Guest 9201 and drill-r50 untouched.
Customer ruling: DELETE (R-93's lesson — no half-real fixtures). Attempted and correctly refused:
delete sess-c REFUSED: host sess-c-8158e4 is ONLINE. The VM is destroyed so no further reports come;
the host ages OK → WARN (30 m) → DOWN (>1 h) and is then deletable. Command, unchanged from E-2d:
POST /configs/sess-c/delete ack_hosts=1 ack_reset=1 ack_purge=1 confirm_id=sess-c expect_hosts=1
9. What did not happen
backup_target_absentnever fired, so its severity, its Hungarian customer copy and its hub routing are all still unexercised end-to-end. R-116 blocks them.- The offer control was accepted via the endpoint it POSTs, not by a browser click — no browser
automation exists on DooPlex. The rendered control, its