gates / gates (push) Successful in 2m11s
hub (unreleased): the operator is told when a box's clock is more than one minute from the hub's (R-1384, D79)
The host report's new sent_at (the box clock at the moment of sending) is compared with the hub's clock at arrival.
Both directions; told once; clears within 30 s. A report that waited on the box raises nothing (reported_at is not
read). A second box off in the same direction points at the hub's own clock. Operator-only. Not deployed.