soak drill phases 0-4: R-408's hazard is REAL and reachable; R-357 finally live (R-411..R-413)
Overnight soak on demo-hp, phases 0-4 of 7. Evidence
documentation/audits/DRILL-soak-2026-08-31/. No production code written, no golden,
no version bump - findings only.

PHASE 1 FAIL - R-411. The R-408 hazard was only ever reasoned about; tonight it was
measured through the product's own endpoints. restic stats TAKES A LOCK (clean-room:
nothing else running, 4x stats, sampler reads locks=1). A customer full-restore runs
stats in its preparation while holding NO acquireRunning, so the integrity check is not
blocked, runs, meets that lock, and resticStep escalates to unlock --remove-all - the
sampler caught "restore ..." and "unlock --remove-all" in the SAME sample at 20:50:51.
The log calls it "a stale exclusive lock left by a previous crash"; there was no crash.
THE CUSTOMER-FACING CONSEQUENCE IS CONTAINED and that is R-359 working: the check was
classified Unreachable, NOT damage, so no alarm and due-ness held. The opposite direction
is FENCED - five restores fired into a running check at 5/15/25/35/40s were all refused by
restoreOpBlocked with zero restic invoked.

PHASE 2 FAIL - R-412, and it is the natural instance of R-403's shape that yesterday's
session had to hand-build. A lost primary unit is rebuilt by the capture WITHOUT its
volume dumps (185664 B -> 4382 B, volume_dumps: None), and the off-site backup then ships
it and logs "backed up opengist ... 0 mandatory path(s)" - a success line over a backup
holding none of the app's data.

PHASE 2 also R-413: the R-87 proof CAUGHT that hollow snapshot unattended -
verdict "fail", volumes_expected_none_captured: opengist_data, one offsite_proof_empty at
severity error, while the four apps ahead of it in the rotation passed.
2.3 stale marker PASS, 2.4 two restores PASS, 2.5 corrected the runbook's premise
(RunTier2 has zero acquireRunning and zero restic references - a local mirror cannot
collide with the repo, so the proof correctly does not skip for it).

PHASE 3 PASS - R-357 live-validated at last, six days owed. A real full filesystem
(1900544 B free vs 5878421 B needed) on a separate 1 TB device that does not back Docker.
Refused BEFORE StopStack: app "Up 6 minutes (healthy)" unchanged, 0 safety dumps, live
userdata tree fingerprint 5a9b2db75dfd4ba4131adb3255670472 unchanged, message names both
numbers in Hungarian. Ballast removed, the SAME restore then worked and the fingerprint is
still identical. On the same full disk the Tier-2 run, the proof and the integrity check
all behaved: the proof refused before any download through the shared unitOnlyHeadroom
gate extracted today, reached no verdict and did not alarm.

PHASE 4 PASS - the false-alarm control the whole R-87 design rests on now EXISTS. Found by
reading all 53 catalogue composes: bentopdf is the only template with neither a database
service nor a named volume. Deployed, backed up, proved: PASSED in 2.224s with zero alarms.

Four of my own instrument errors were caught by their own controls before any result was
believed: a hub log line used as a controller positive control, a grep pattern that missed
a registered job, a heredoc that mangled a planted marker, and a catalogue scan that read
0 of 0 apps from the wrong path.

Phases 5-7 to follow: the real nightly cycle with injected faults, the untouched observer,
and teardown.
2026-08-31 23:33:32 +02:00

11 lines
236 B
Plaintext

=== QUIET PERIOD: the sampler must report 0 ===
20:43:04 locks=0
20:43:09 locks=0
=== POSITIVE CONTROL: integrity check at 100% depth, which holds a lock (R-407) ===
[http=200 wall=43.938650s]
=== the sampler must have SEEN it ===
8