Full ISO/PAIRING run on a fresh nested box. Agent 0.114.0 came from the Day-0 manifest -- the SHIPPED binary -- so C5 tested the real artifact. Controller 0.186.0 hand-deployed after install per the §3.1 ruling; the vouched golden bakes 0.185.1, so C3/C4 prove the code not the shipped golden, and that lag is filed against R-115 rather than a new ID. R-113 PROVEN: detach 18:43:50, gate fired 18:43:54 -- four seconds, where E-2d measured zero over 4.5 minutes -- and SetDisconnected was reached. It fired on exactly the shape that defeated it: raw /mnt/mentes NOT mounted while the bind /mnt/felhom-drives/mentes still read /dev/sdb[/felhom-data]. R-114 PROVEN: with the target absent the page rendered the absent copy, the system-disk copy 0 and the offer block 0. Both of E-2d's falsehoods are gone. R-112 PROVEN: the banner reached a customer's page for the first time. Healthy renders nothing, proven POSITIVELY -- idle delta 0 /backup/tiers calls, page load delta +1, single caller, so the seam ran and chose silence. C5 FAILED on a fourth, separate defect. The alarm fires but as the GENERIC storage_disconnected, while the recovery is the SPECIFIC backup_target_restored -- a pair an operator cannot match, which is what notifyDriveReturned's own comment forbids. backup_target_absent count 0 across the run. Root cause: the drive is TWO /disks rows and BackupTarget and GuestPath sit on different ones; absent they separate, on return they rejoin. v0.184.1 fixed the keying, not this. Only reachable because R-113 made the gate fire at all. Filed as R-116. Mirror + over-correction guard PASS: non-target drive -> storage_disconnected, backup_target_absent 0; both drives present -> 0 ABSENT lines and the target stayed healthy. Caveat recorded: the mirror passes trivially because the target also produced the generic event. E-2 and E-2d CLOSED as partially proven with R-116 the one named open leg, per the runbook's §9 rule decided in advance rather than mid-run. Capability map NOT touched: it has no E-2 rows at all, so nothing could move to PROVEN-LIVE. Creating them is a design act, not a validation act. Teardown clean: pvesm status after == before (local-lvm 38.78%), guest 9201 and drill-r50 untouched. Customer delete attempted and correctly refused while the host still reads ONLINE; command recorded for once it ages to DOWN.
4.9 KiB
REPORT — Session C: R-113, R-114, R-112 proven on a real box; C5 fails on a new defect (2026-07-29)
RUNBOOK-session-c-2026-07-29.md. Full evidence: documentation/audits/SESSION-C-2026-07-29.md.
Root REPORT.md untouched.
Verdicts
| Claim | Fix | Verdict |
|---|---|---|
| C4 — offer appears and moves the target | R-112 | ✅ PASS |
| C3 — absent target tells the truth, offers nothing | R-114 | ✅ PASS |
C5 — backup_target_absent + backup_target_restored |
R-113 | ❌ FAIL — generic alarm, specific recovery → R-116 |
All three shipped fixes work. R-113's gate fires in 4 seconds (E-2d measured zero over 4½ minutes). R-114's message is correct. R-112's banner reaches the customer. C5 fails on a fourth, separate defect that was unreachable until R-113 made the gate fire at all.
What the drill box ran
Agent 0.114.0 from the Day-0 manifest — the shipped binary, so C5 tested the real artifact and closed R-115's observation 1 for R-113. Controller 0.186.0 hand-deployed after install (§3.1 ruling (a)); the vouched golden bakes 0.185.1, so C3/C4 prove the code, not the shipped golden — that lag is filed against R-115, not a new ID.
The three headline observables
R-113 — detach at 18:43:50, gate at 18:43:54, on exactly the shape that defeated it before:
raw /mnt/mentes : NOT mounted
bind /mnt/felhom-drives/mentes : /dev/sdb[/felhom-data] <- the stale bind SURVIVED
R-114 — with the target absent: absent copy 1, system-disk copy 0, offer block 0. Both of E-2d's falsehoods gone.
R-112 — banner element 1 and the never-configured copy in the HTML; after the wizard, the offer
with data-path="/mnt/felhom-drives/mentes". Healthy renders nothing, proven positively: idle
delta 0 /backup/tiers calls, page-load delta +1, single caller ⇒ the seam ran and chose silence.
Decline path proven (registration confers no role), restart_required:true, agent did not
self-restart, in-flight check recorded before I restarted it, wrapper created the storage at the
drive's own mountpoint.
C5's failure
absent : Event pushed: storage_disconnected (error) <- GENERIC
return : Event pushed: backup_target_restored (info) <- SPECIFIC
backup_target_absent count 0 across the whole run. The alarm and its recovery cannot be matched
— precisely what notifyDriveReturned's own comment forbids.
Root cause (R-116): driveTargetByPath builds out[GuestPath] = d.BackupTarget, but the drive is
two /disks rows and the flag and the guest path sit on different ones — the felhom-backup
storage row carries BackupTarget: true and gets a guest path only while classified user-data; the
registry union row carries the guest path and never assigns BackupTarget. Absent ⇒ they separate
⇒ generic. Return ⇒ they rejoin ⇒ specific. v0.184.1 fixed the keying, not this.
Mirror + over-correction guard — PASS, with a caveat
Non-target drive detached ⇒ storage_disconnected, backup_target_absent count 0. Over-correction
guard passes: both drives present ⇒ 0 ABSENT lines, target stayed healthy — R-113's stricter presence
did not make a healthy drive read absent. Caveat: the mirror passes trivially, because the target
also produced the generic event; it confirms no over-correction but cannot confirm discrimination.
Record
OPEN-ITEMS.md— R-113, R-114, R-112 → SHIPPED + PROVEN-LIVE; R-116 opened (READY (S), P1); E-2 and E-2d CLOSED as partially proven with R-116 as the one named open leg, per the runbook's §9 decided-in-advance rule.ROADMAP.md— R-116 under P1.- Capability map NOT touched — it still has no E-2 / backup-target rows at all, so no row could be moved to PROVEN-LIVE. Creating them is a design act, not a validation act. Third session running that this has been noted.
Teardown
VM destroyed, storage removed, pvesm status after == before (local-lvm 38.78 %), guest 9201 and
drill-r50 untouched. Customer ruling: DELETE; attempted and correctly refused (host … is ONLINE) — deletable once the destroyed host ages to DOWN (>1 h), command recorded in OPEN-ITEMS.md.
What did not happen
backup_target_absent never fired, so its severity, Hungarian copy and hub routing remain unexercised
— R-116 blocks them. The offer was accepted via the endpoint the button POSTs, not a browser click (no
browser automation on DooPlex); the rendered control and its non-auto-submission were verified in HTML.
The stale bind still naming a dead device node after return was observed, not investigated.
The arc