Files
felhom.eu/REPORT-poweroff.md
T

5.0 KiB
Raw Blame History

REPORT — the „turn the machine off" button: spike on the N100, then built and proven (2026-10-13)

Architecture: documentation/architecture/14-host-power-off.md (new), 03-host-agent.md §6, 13-threat-model.md, 05 staleness. Evidence: documentation/audits/poweroff-2026-10-13/README.md (Part A, Part B, HP). Times UTC.

1. Watts and the restart

Item Value
N100 at rest 8.5 W mean, 7.2 W median
N100 at work (Immich, 200 photos) 20.7 W mean, 24.0 W busiest minute, 25.2 W max
N100 off 0.0 W (below the plug's 0.1 W step), 2 h 56 min
N100 plug off/on did not start (BIOS not read — no monitor)
N100 power button Part A: dashboard 200 in 42 s. Part B: dashboard 200 within 50 s
HP t740 off, plug on 0–3.2 W
HP after a power cut did not start (BIOS „After Power Loss" Off) → operator set „Previous State" → starts by itself, controller healthy 2 min 38 s after power returned

2. The hub during the hand test (Part A, before the build)

Item Result
18 min after power-off hosts page ONLINE, „Last Report 18 min ago"; no event, no mail
Code reading without the build: host_stale at 45 min, host_down at 90 min, and the 05:00 expected_backup_missed pair — as Tester 2 gets every day

3. The button

Who What they see
Household Beállítások → Rendszer → „A gép kikapcsolása". They type KIKAPCSOLÁS (EN: TURN OFF). Text: to start it again, press the machine's power button. The plug trick is not mentioned. Refusals in plain words: too soon after start, already done this boot, backup, update, drive work, another machine running
Old restart button now „A Felhom újraindítása" / „Restart Felhom" (R-999); reboot is POST only
Hub event host_deliberate_off at once; host page „Power: Kikapcsolva a háztartás által … riasztás szünetel eddig: +14 days"; badge KIKAPCSOLVA once the report is stale (45 min — R-1002); no stale/down/backup/offsite/restore-test/OS alarm for 14 days; OS ring-0 stall is still raised on purpose
Hub, machine back host_deliberate_off_ended (info) with the first report; staleness back to ok; no *_recovered, no crash mail
Live proof press 18:52:34 → 202 → 0.0 W 18:53:07 → 2 h 56 min quiet (mailbox checked; positive control: the HP crash mails arrived) → button 21:48:43 → clean boot → hub cleared 21:49:22

4. Versions and what waits on the operator

Part Version Where
Agent v0.155.0 + config bundle all three boxes by signed job; sudo checked live on each
Hub v0.149.0 live (ArgoCD, hub Deployment only)
Controller v0.310.0, MinAgent 0.155.0 N100 guest 9201 only, by hand
Waiting on the operator If nothing is done
Golden bake (weekly) the waiver covers it until 2026-10-20
Vouch agent 0.155.0 + bundle a fresh install gets 0.154.0, without the power-off lines
Floor 0.310.0 with min_agent 0.155.0 demo-hp and Tester 1 keep 0.309.0: no button there
N100 BIOS „After Power Loss" unknown; a deliberately-off N100 stays off after a power cut (looks like „last state")
HP BIOS: „Bypass F1 on configuration changes" → Enable a changed BIOS can stop the HP at an F1 prompt after a cut

5. Claims in the spec that were wrong

Claim What is true
„guestpower.go guards a reboot during a vzdump" only the watchdog path does; the new route takes the heavy-operation gate itself
„the plug can be switched; the spike runs without the operator" the N100 does not start on plug power; the operator pressed the button twice
A0 „never cut a running machine" as written needed a measured standby value first (standby_w) and a 20 s reading window; the first live off refused on 16 s

Decisions taken in the session (doc 14): refuse while another guest or VM runs; os_ring0_stalled not held; the unaccented KIKAPCSOLAS accepted; the golden waiver renewed to 2026-10-20 to let the hub deploy pass its gate.

6. Commits, register, STATUS

Repo Commits
felhom.eu 6a1f715a, b4dcf4b3, 750b55e9, 50e47e29, a6acb0f7, 35e546a9, e8c8fc30, 81e64c6f, 0544ae0d, 95d293b9, and this one
felhom-agent 3403c87, f38b03c, c6d9435, bdf25f0, 68a2130, 10ca63a, e7d4ecd
felhom-controller 201f936, e24430c, acbbf4b

Register: 125 before, 127 after. Opened R-998, R-999, R-1000, R-1001, R-1002 (5). Closed R-998, R-999 (2). R-997 was closed by another session in between (−1).

Fixed without a row: an escrow-ceremony data race (agent); plugswitch read window (bench tool); my wrong os_ring0_stalled sentence in the hub CHANGELOG and doc 14.

Teardown: machine — the N100 and the HP run as before, Immich removed in Part A; host — no change left on either host apart from the released agent and bundle; hub — the hold was set and cleared by the product. The bench meters are stopped. Home Assistant on demo-hp stays (Task 1, on purpose).

System poster: no fact in felhom-system-poster.facts.md changed.