PART 1+2 — dated checks stop being wishes. R-341 booked two measurements as prose in a register row; nothing read those dates and nothing would have objected when they passed. The dates now live in a DUE-CHECKS block INSIDE OPEN-ITEMS.md (inside, so no sidecar can drift from it) and a new gate reads them. Registered as #10 in repo_gates.py, --fast, so it runs in BOTH the pre-push hook and CI. exit 0 nothing due (prints pending count + nearest date; empty block too) exit 1 a row is due/overdue (due <= today, UTC -- due TODAY counts), or a row names an item with no R-row exit 2 block absent/duplicated/unparseable -- INCONCLUSIVE, never 0 It REFUSES rather than warns, and its docstring states the limitation: it is NOT a scheduler, it fires on the next push, not on the date. 37 tests. BOTH red-proofs run and reverted -- and the first one earned its keep by catching a hollow assertion of MINE rather than confirming the gate: flipping <= to < left a due-today row in neither bucket, min() raised on an empty list, and the TRACEBACK exited 1, so "rc == 1" passed while the boundary was wrong. An exit code cannot tell a verdict from a crash. The test now asserts the conviction banner and the absence of a traceback, and the gate returns 2 rather than crashing if that partition breaks again. PART 3 — the floor raise, and the premise was WRONG. Read back from the store (not the form): min_controller_version = 0.216.0 @ 12:36:58Z, zero per-customer overrides, no "managed floor HELD" line. But read 5 shows the raise was NOT a no-op: demo-felhom had been on 0.214.0 since 12 Aug and auto-updated 0.214.0 -> 0.216.0 at 12:37:07Z -- NINE SECONDS after the save, exactly the immediate action publish-train rule 2 documents. No error events followed; it restarted clean. R-343 is therefore filed OPEN, not CLOSED: the closing condition was all five reads clean and no directive served. It went well, but a record calling it inert when it moved a customer box is what misleads the next reader. The row also states why the floor was behind -- rule 2 policy, not drift, earned by the 2026-07-11 skew onto Peti's box -- and cites ResolveManagedFloor (store.go:2068) plus the two build-felhom-iso.sh facts (build-time at :267, fails open at :78-82) rather than asserting them. Two boxes are below the floor and neither reports: drill-r50 (blocked, powered off) and peti-felhom (host row deleted). peti-felhom was NOT contacted -- its row records that a report from a deleted host 401s and is not persisted, so the raise cannot reach it. PART 4 — R-342 filed READY, quoting stop2-snapshot.txt verbatim: Hetzner server snapshot 421440873 covers /dev/sda only; /mnt/pbs-datastore is a separate Volume that snapshots exclude, so a rollback restores software state and NOT the datastore. Fine for that upgrade; the safeguard for any future procedure that could touch the datastore does not exist and is Viktor's call. Also: CLAUDE.md's gate list named 6 of 10 registered gates -- completed rather than appending a 7th to a wrong list (124 -> 128 effective, ceiling 200). Capability map deliberately unchanged; no row cites a floor or golden version. repo_gates.py fully green, 10/10.
11 KiB
STATUS — what works, what's broken, what's next
Updated 2026-08-18 (afternoon — a listening socket that served nobody, a rehearsal upgrade that changed nothing, and a new install that is finally current).
A view, not a source.
documentation/backlog/OPEN-ITEMS.mdis the authority; this page restates part of it in plain words, and nothing may exist only here. Items, not paragraphs. One screen. If it does not fit, it belongs in the register instead.
Waiting on you
Nothing. All three questions that stood here were answered on 12–13 August and have moved to Decided below. A decided question left in the deciding list is how a person loses track of what is actually waiting.
Decided — and what would reopen each
A decision with no trigger becomes a permanent silence, so each one names what would make us look again.
- Getting old backups back yourself: NOT BUILT, deliberately. A customer in that position is a support conversation, and we can do it by hand. Reopens if: a real customer actually asks — one request from a person who is not us. (register: R-312)
- The unopenable old copy on
demo-felhom: KEPT, as a test fixture. Not for sentiment: it is the only state in existence where a set-aside store is present and cannot be opened, which is the case any future handling of lost backups has to face honestly. Delete it when: that work ships, or is abandoned. Until then it is a fixture, not an accumulation. (register: R-313) - A machine in two kinds of trouble says both things: LEFT AS IT IS. Its real-world likelihood is unknown, and hiding one card risks hiding a real second failure. Reopens if: it is observed happening outside a constructed test. (register: R-303)
What works
Both demo machines are home, healthy and reporting on the approved pair — controller 0.214.0, agent
0.129.0, delivered by the floor rather than by hand. Off-site is credentialed on demo-hp and its
repository still opens with the machine's own key. drill-r50 is reverted to virgin, powered off.
What the fleet actually is, because two summaries have now been misread: the hub holds five
customer records and three machines. The machines are demo-felhom and demo-hp (both ours, both
disposable) and drill-r50 (a nested drill VM on DooPlex, reverted and powered off). peti-felhom
is a real machine we have not heard from since 15 July and has no host record. tester-1 is a
record with no machine — created 13 August, no host, no backups, nothing to lose.
Shipped
-
The auto-update floor is current again (R-343). You raised it to today's version this afternoon. It was not left behind by accident — our own rule says the floor is raised last, after the image is vouched, because it acts within seconds. It did: one machine updated itself nine seconds later and came back up cleanly. Worth knowing that raising it is a fleet action, not paperwork.
-
A dated check can no longer be quietly missed (R-341). When we write "measure this again on the 19th", that date is now read by the build system, and a push is refused once it passes. It is not a reminder service — it speaks on the next push, not on the day — and that limit is written into the check itself.
-
A new machine installed today finally gets today's software (R-334, closed). The pre-built image had been two releases behind since the 14th — anyone installing would have received a version missing last week's disk-warning fix and the follow-up that corrected it. A fresh image was baked and published, and you vouched it, which was the half that could not be done without you. The build system is green again for the first time since 14 August, so the failure mail should stop. The running machines were not touched: this only ever affected new installs.
-
Last night's two backup alarms were real, and are fixed (R-336). Both machines failed their off-site backup at 04:30; neither machine was at fault. The off-site box in Germany had run out of one internal resource and, while looking perfectly healthy from outside, was accepting no connections at all — for 9½ hours. Restarted, given a ceiling 64× higher, and both missed backups were re-run the same morning and are on the off-site box. Nothing was lost and nothing was skipped: the daily copies on the machines themselves were never affected, and the off-site copy is weekly, so exactly one attempt fell in the window. The underlying cause — we ask that box a question about once a second, all day — is filed and not yet fixed; the raised ceiling buys under a year on the corrected measurement, not a cure.
-
The removal now genuinely reverses the installation (R-316,
installer-v1.28.0published). The second reinstall used to hit our own leftover; it was watched failing on the cycle that actually fails, then watched passing. -
A correct recovery code is no longer called wrong (R-311, three components). If a customer types the code for an older set of backups, the machine now checks the packages we kept, recognises it, and says so: your code is correct, it belongs to an earlier package, we kept it, your current backups are fine, write to us. It deliberately promises no restore, because there is no button yet.
-
The drive can be re-attached after a reinstall (R-280), and the orphan card and the countdown banner stop promising retrieval they cannot see is still true (R-294, R-299, R-302).
-
One name per secret — now both halves (R-295). The dashboard code is „Beállító kód" everywhere, on the machine and in the hub's emails; „Visszaállító kód" is retired. It collided with the escrow „Helyreállítási kód" and cost a real code.
-
The hub can see whether a machine's guest still has working networking (R-319, first reader built against R-264). A machine quietly repairing its own network over and over is now visible instead of being a green tick; a machine that does not report it is drawn as unknown, never as healthy.
-
The third secret has its own name (R-323, on your ruling). The five-word phrase that proves an account owns the box being linked is „Tulajdonosi jelmondat". It was „Visszaállító jelszó" — one word from the name we retired last week, and false besides: it restores nothing. Five places, all in the hub; no machine touched.
-
A machine we tell to be quiet is no longer reported as dead (R-321). It went stale, then down, then e-mailed you twice about a silence you asked for. It turned out to be two alarms, not one — the morning backup reminder had the same blind spot and is fixed with it.
-
The hub's own words are under a guard (R-324). Every customer e-mail and the linking pages are now checked for a retired name, and the guard has been watched catching one, ignoring an explanation of one, and going quiet again.
-
The countdown on
demo-felhomis cancelled on your ruling (R-307). Nothing was deleted.
Broken, or knowingly incomplete
-
We interrogate the off-site box about once a second (R-336). Roughly 85,000 questions a day, for a box we actually write to once a week. That volume is what turned a slow internal leak into last night's outage in a fortnight. The higher ceiling makes it rare, not impossible — the leak itself is untouched. The honest health check is the resource count climbing, not the absence of an alarm. Corrected later the same morning: my first estimate of how fast it leaks was too optimistic by about 2.5× — measured properly it is under a year to the new ceiling, not two years. A deadline, not a comfort.
-
The off-site box was updated, and it did not help — as expected (R-341). On your ruling we installed the newer backup software for the practice, having first read its release notes and found nothing about the fault we have. The update went cleanly and everything works, but the leak behaves exactly as before, which is the result the release notes predicted. Two dated checks are booked — 19 August and 25 August — because half an hour of watching cannot honestly settle it.
-
One machine's status took several minutes to admit a backup had worked (R-337).
demo-hpwas still showing this morning's failure for four minutes after the copy was safely on the off-site box;demo-felhomupdated in under a minute. It corrected itself and both machines now read correctly, so this is a note to watch, not something broken — but during the repair it looked briefly like a second fault, which is the reason it is written down. -
demo-hpis not set up the way our own notes say it is (R-338). Our inventory records both machines as moved onto the isolated internal link last July.demo-felhomwas;demo-hpwas not — its control channel is still bound to the ordinary home network, which is exactly what that change existed to stop. The machine works; the page is wrong, and it misled this session by an hour. Your call which one to correct. -
Peti's machine has no recovery route at all — see the
PETIrow. This is a real machine belonging to a real person, not one of ours and not a record: it reported to the hub for four and a half months and has been silent since 15 July, when its host record was deleted. There is no key, no off-site copy and no local backup. If that drive fails, everything on it is lost. First act of the visit: copy the ~3.6 GB off before anything is reinstalled — it is currently the only copy in existence. Whether it stays parked is your call and is deliberately left open. -
Kept backups can be opened — but still only by us (R-304 partly closed, R-312 decided-not-built). Today the honest answer is "your code is right, write to us" — and we can.
-
The agent picks dnsmasq by looking at a file another package owns (R-317). The box installs fine; only LAN name resolution goes missing, and quietly. One line, deliberately not taken tonight.
-
The storage page has its own separate reason for showing an empty list (R-298), untouched.
-
Three more facts the machines send still have no reader (R-264): a staged-but-unapplied agent update, how deep a restore test actually went, and the two backup-integrity timestamps. Five others are now recorded as deliberately unread, which is honest rather than fixed.
-
Two thirds of the standing picture is still unproven, and now you can ask (R-326).
python3 scripts/unproven.pylists it: of 55 claims, 23 are walked and 32 are not — and of those 32, only 6 point at an evidence document. The "nine" I have been repeating was wrong: nine is how many claims the 9 August review lowered, which is a different question. -
The picture still describes one defect we have since fixed twice (R-327) — the naming claim. Its status may only be raised after the capability map moves first, which is a separate judgement.
Working on next
demo-hp is yours this evening — this session did not touch it. After that: the three remaining
R-264 readers, now that one has been built and we know what one costs; R-317 (one line in the agent);
R-327 (decide what the naming claim's status should be); then the 2026-08-09 batch (R-279 … R-292),
still untriaged against everything since.