docs(audits): first genuinely failing disk — the SMART PASSED trap
gates / gates (push) Successful in 12s
gates / gates (push) Successful in 12s
Commit the raw evidence from ST3000VX010 S/N Z6A07P2G (/dev/sdg on DooPlex), which went 8 -> 352 unreadable sectors 11-13 Aug while smart_status.passed stayed true throughout. - fixtures/smart-ST3000VX010-failing-2026-08-14.json: raw smartctl -a -j, verbatim - fixtures/smartd-history-sdg-2026-08-14.txt: 406 smartd journal lines, 11-14 Aug - DIAG-smart-passed-trap-2026-08-14.md: the mechanism (attrs 187/197/198 all carry thresh 0, so a normalized value that floors at 1 can never fail the overall verdict on unreadable sectors), the non-monotonic timeline, the three controller defects with locators, and the counterfactual: zero emails would have been sent.
This commit is contained in:
@@ -0,0 +1,196 @@
|
||||
# DIAG — the SMART `PASSED` trap, and the disk alert that reached nobody
|
||||
|
||||
**Date:** 2026-08-14
|
||||
**Drive:** Seagate `ST3000VX010-2E3166`, S/N `Z6A07P2G`, 3.0 TB, `/dev/sdg` on **DooPlex**
|
||||
**Fixtures:** `fixtures/smart-ST3000VX010-failing-2026-08-14.json` (raw `smartctl -a -j /dev/sdg`),
|
||||
`fixtures/smartd-history-sdg-2026-08-14.txt` (406 `smartd` journal lines for this device, 11–14 Aug)
|
||||
**Status:** the three controller defects named here are FIXED in controller **v0.215.0**; the
|
||||
counterfactual in §5 is derived from source, **not** reproduced live.
|
||||
|
||||
This is the project's first genuinely failing disk. Before it, the capability map recorded the
|
||||
disk-failure scenario as *"Healthy path only — a genuinely failing disk has never been seen."*
|
||||
|
||||
---
|
||||
|
||||
## 1. What happened
|
||||
|
||||
On **11 August 12:28** a 3 TB drive in DooPlex reported its first unreadable sectors. By **13 August
|
||||
21:58** it was at 360, and it was taking down a running service. Throughout the entire episode the
|
||||
drive's own overall self-assessment read **`PASSED`**, and it still does.
|
||||
|
||||
`smartd` was running the whole time and mailed **local root** — a mailbox nobody reads. The failure
|
||||
was actually found by a crashlooping pod, not by any alert.
|
||||
|
||||
---
|
||||
|
||||
## 2. The mechanism — `smart_status.passed` cannot fail on unreadable sectors
|
||||
|
||||
Measured, from the committed fixture:
|
||||
|
||||
| ID | Attribute | value | worst | thresh | raw |
|
||||
|-----|--------------------------|-------|-------|--------|--------|
|
||||
| 5 | `Reallocated_Sector_Ct` | 100 | 100 | **10** | 0 |
|
||||
| 187 | `Reported_Uncorrect` | **1** | **1** | **0** | **1001** |
|
||||
| 188 | `Command_Timeout` | 100 | 100 | **0** | 0 |
|
||||
| 197 | `Current_Pending_Sector` | 98 | 98 | **0** | **352** |
|
||||
| 198 | `Offline_Uncorrectable` | 98 | 98 | **0** | **352** |
|
||||
| 199 | `UDMA_CRC_Error_Count` | 200 | 200 | **0** | 0 |
|
||||
|
||||
`smart_status.passed` is false only when some attribute's **normalized value** falls **at or below**
|
||||
its **threshold**. Attributes 187, 197 and 198 — the three that record unreadable sectors — all carry
|
||||
`thresh: 0`. A normalized SMART value floors at 1 and cannot reach 0.
|
||||
|
||||
> **Therefore `smart_status.passed` is structurally incapable of failing on unreadable sectors.**
|
||||
> This is not a quirk of this drive or this vendor. It is how a zero threshold behaves.
|
||||
|
||||
Attribute **187 `Reported_Uncorrect` sits at normalized `1` against threshold `0`** with a raw count
|
||||
of **1001**. It is one point from failing and has no remaining point to give.
|
||||
|
||||
Corroborating, from the same fixture: `ata_smart_error_log.summary.count = 1001`, power-on hours
|
||||
**60505** (~6.9 years), `smartctl` exit status **64** (bit 6 — *the device error log contains
|
||||
records of errors*) while `smart_status.passed` is still `true`.
|
||||
|
||||
**Any monitor built on the drive's overall verdict is blind to this entire class of failure.**
|
||||
Felhom already knows better — `agentapi.DiskVerdictFor` reads the raw counters — which is why it
|
||||
would have noticed on 11 August, two days early.
|
||||
|
||||
---
|
||||
|
||||
## 3. Unreadable sectors are not monotonic
|
||||
|
||||
From `smartd-history-sdg-2026-08-14.txt`, `Current_Pending_Sector` over the episode (30-minute
|
||||
sampling, host clock = CEST):
|
||||
|
||||
```
|
||||
Aug 11 12:28 8 first sighting
|
||||
Aug 11 12:58 16 (+8)
|
||||
Aug 11 13:28 0 FULL CLEAR — "No more Currently unreadable (pending) sectors,
|
||||
warning condition reset after 1 email"
|
||||
Aug 11 20:28 8 returns
|
||||
Aug 12 01:28 16 → 01:58 8 (-8)
|
||||
Aug 12 02:28 32 → 02:58 24 (-8)
|
||||
Aug 12 03:28 24 187 Reported_Uncorrect 100→97; ATA error count 0→3
|
||||
Aug 12 03:58 16 (-8) → 04:28 24 (+8)
|
||||
Aug 12 10:58 32 … steady 32 for ~11h …
|
||||
Aug 12 21:58 24 (-8)
|
||||
Aug 13 03:28 40 (+16) → 04:28 24 (-16)
|
||||
Aug 13 11:28 64 terminal run begins — never returns below 64
|
||||
Aug 13 11:58 72 12:58 80 13:28 112 15:58 120
|
||||
Aug 13 21:58 360 (+240)
|
||||
Aug 13 22:28 352 (-8) … steady 352 through 14 Aug …
|
||||
```
|
||||
|
||||
Two measured facts carry design weight:
|
||||
|
||||
1. **The 11 August excursion cleared completely within one hour** (12:28 → 13:28). A bare `> 0`
|
||||
alarm would have fired on a drive that then looked fine for seven hours. This is why the ladder
|
||||
uses a *sustain* rule rather than a bare non-zero test.
|
||||
2. **The benign excursion peaked at 16; the terminal run crossed 64 at 13 Aug 11:28 and never came
|
||||
back.** That is the entire empirical basis for the static count threshold of 64 — see §6.
|
||||
|
||||
---
|
||||
|
||||
## 4. The three controller defects
|
||||
|
||||
All three are in `felhom-controller` at `3e3ee94` (v0.214.0), the tree audited here.
|
||||
|
||||
### D1 — the alert carries a severity the hub does not recognise *(highest value)*
|
||||
|
||||
`internal/notify/notifier.go:565` — `NotifyDiskHealthDegraded` sets:
|
||||
|
||||
```go
|
||||
severity := "warn"
|
||||
```
|
||||
|
||||
The hub accepts an exact-match lowercase vocabulary and **coerces anything else to `info`**:
|
||||
|
||||
- `felhom.eu/hub/internal/api/handler.go:2121-2126` — `case "info", "warning", "error", "critical":`
|
||||
… `default: payload.Severity = "info"`
|
||||
- `felhom.eu/hub/internal/notify/dispatcher.go:89-96` — `severityNotifies` returns true only for
|
||||
`warning` / `error` / `critical`.
|
||||
|
||||
`"warn"` is not in the accepted set. So the Figyelmeztetés-level disk alert is **stored as an
|
||||
informational notice and emailed to nobody**, on the customer leg and the operator leg alike.
|
||||
|
||||
The function's own doc comment reads *"The hub applies its own per-event-type cooldown"* — which
|
||||
presumes it routes. An invariant asserted in a comment with no test pinning it; this project's
|
||||
recurring shape.
|
||||
|
||||
### D2 — no level above "worth keeping an eye on it"
|
||||
|
||||
`internal/agentapi/diskverdict.go:28-41` returns `Warn` for *any* non-zero counter, and can only
|
||||
reach `Fail` when `Health == "FAILING"` — which, by §2, this fault class cannot produce. A drive with
|
||||
one aging sector and a drive at 352 unreadable sectors rendered the identical chip and the identical
|
||||
mild sentence.
|
||||
|
||||
### D3 — it speaks once, and forgets on restart
|
||||
|
||||
`internal/web/disk_health.go:182` emits only on `v > prev`, against a **in-memory** baseline
|
||||
(`disk_health.go:26-29`, *"Lost on restart → the next check re-baselines silently"*). Consequences:
|
||||
|
||||
- Between 8 and 352 pending sectors the verdict never changes level, so **nothing further is emitted**.
|
||||
- A controller restart while a disk is already bad re-baselines it silently — that disk never alerts
|
||||
again.
|
||||
|
||||
---
|
||||
|
||||
## 5. Counterfactual — what a customer would have received
|
||||
|
||||
**Derived from the source above plus the §3 timeline. NOT reproduced live.**
|
||||
|
||||
| Date/time | Drive state | Felhom verdict at v0.214.0 | Emitted | Delivered |
|
||||
|-----------|-------------|-----------------------------|---------|-----------|
|
||||
| 11 Aug 12:28 | pending 8 | OK → Figyelmeztetés | `disk_health_degraded`, severity `warn` | **nothing** — coerced to `info`, dropped by `severityNotifies` |
|
||||
| 11 Aug 13:28 | pending 0 | Figyelmeztetés → Rendben | none (recovery is silent) | nothing |
|
||||
| 11 Aug 20:28 → 13 Aug | 8 → 352 | Figyelmeztetés throughout | none (no level change) | nothing |
|
||||
| 13 Aug 21:58 | pending 360 | Figyelmeztetés | none | nothing |
|
||||
|
||||
> **Felhom would have emitted zero emails about this drive.** The one event it did produce was filed
|
||||
> at `info` and delivered to no one.
|
||||
|
||||
Note the two defects compound: even had D1 been fixed alone, the customer would have received a
|
||||
single mild "Javasolt figyelemmel kísérni" at 8 sectors on 11 August and then silence through 352.
|
||||
|
||||
---
|
||||
|
||||
## 6. Provenance of the thresholds chosen in v0.215.0
|
||||
|
||||
- **64 unreadable sectors → Hiba.** The observed benign excursion peaked at **16** and cleared inside
|
||||
an hour; the terminal run passed **64** at 13 Aug 11:28 and never returned below it. 64 sits above
|
||||
the one observed transient and below the observed terminal run. **This is a judgement from ONE
|
||||
drive.** It is a static backstop and is expected to be replaced in Phase 3 by growth-rate detection
|
||||
over real history.
|
||||
- **Sustain before count.** The primary rule is "unreadable sectors still present at the next check";
|
||||
the count is the backstop. On this drive sustain fires **12 Aug**, the count not until **13 Aug** —
|
||||
a full day earlier. The backstop exists for a box that was powered off or restarted across the
|
||||
sustain window.
|
||||
- **55 / 60 °C.** Adopted unchanged from the operator's existing Prometheus bands on DooPlex, so the
|
||||
two systems cannot disagree about the same drive.
|
||||
|
||||
---
|
||||
|
||||
## 7. Measured vs inferred
|
||||
|
||||
**Measured** (reproducible from the committed fixtures):
|
||||
- The attribute table, thresholds and raw values in §2; `passed: true` at 352 pending sectors.
|
||||
- The full non-monotonic timeline in §3, including the one-hour full clear.
|
||||
- The three defect locators in §4 — read from live source on both the controller and the hub side.
|
||||
|
||||
**Inferred** (source-derived, not executed):
|
||||
- The §5 counterfactual. It follows from the §4 locators and the §3 timeline; **no email path was
|
||||
exercised against this drive**, and no `disk_health_degraded` event for it exists in the hub.
|
||||
|
||||
**Not covered here:**
|
||||
- Attributes **187**, **199** and **188** are not on the agent→controller wire today. Adding them is
|
||||
Phase 2 (a declared wire change, so the hub models them in the same session under G-1). Everything
|
||||
the v0.215.0 fix needs was already on the wire.
|
||||
- The new Fail-from-counters path has **not** fired on real hardware — only against this fixture's
|
||||
values in unit tests.
|
||||
|
||||
---
|
||||
|
||||
## 8. One layer out
|
||||
|
||||
`smartd` on DooPlex did its job and mailed local root, where nothing reads. That is the same shape
|
||||
as D1 — a correct detection with a delivery path to nowhere — one layer outside the product. Tracked
|
||||
separately as DooPlex hygiene.
|
||||
Reference in New Issue