Bench: plugmeter reads the N100's metered plug (tinytuya + Home Assistant from the catalog)
gates / gates (push) Successful in 6m43s

scripts/bench/plugmeter.py prints watts/mA/V/kWh as CSV from the Tuya plug on the LAN
(default) or from Home Assistant on demo-hp's guest. 10-minute side by side and a
3-minute control in documentation/audits/plugmeter-2026-10-13/: Home Assistant alone
did not move for 3 minutes, so the LAN reader is the measurement source.
No key, device id or token in the repo; secrets scan 0 hits with a positive control.
This commit is contained in:
admin committed 2026-10-13 17:07:26 +02:00
1 parent fc0441348d
commit 6a1f715a87
9 files changed
+915

No files matched your search

+33
View File
@@ -0,0 +1,33 @@
# scripts/bench — bench tools that run on DooPlex
## plugmeter.py — the N100's power meter
The N100 demo box (`demo-felhom`) is on a Tuya Wi-Fi plug with a power meter. `plugmeter.py` reads it and
prints CSV (`utc_time, watts, milliamps, volts, kwh_total`) every `--interval` seconds (default 2).
```
~/.venvs/plugmeter/bin/python scripts/bench/plugmeter.py --once # one reading
~/.venvs/plugmeter/bin/python scripts/bench/plugmeter.py --duration 600 > a.csv # 10 minutes
~/.venvs/plugmeter/bin/python scripts/bench/plugmeter.py --source ha --once # through Home Assistant
```
- **`--source tuya` (default) — use this for measurements.** It talks to the plug on the home LAN and
makes it re-measure on every read; a new value every 2 s. Each value is the plug's previous measurement
(it answers a refresh with what it holds), so a row lags by about one interval. About one read in four takes
up to 8 s instead of 2 s; the row is late, not lost.
- **`--source ha` — the backup.** Home Assistant on demo-hp's guest (`https://ha.enkisfelhom.hu`, installed
from the Felhom catalog) reads the plug through Tuya's cloud. **On its own it did not change for 3 minutes**
(2026-10-13); it moves only when something makes the plug report — the tuya reader does. It keeps history and graphs. Its `felhom-bench` user is local-access-only, so the tool connects
to the guest's LAN address and still checks the certificate by name.
Setup (done 2026-10-13, `documentation/audits/plugmeter-2026-10-13/`): a user venv
(`python3 -m venv ~/.venvs/plugmeter && ~/.venvs/plugmeter/bin/pip install tinytuya`), and the files under
`~/.config/felhom-bench/` (700; every file 600): `plug.json` (device id, local key, address, data points),
`ha.json`, `ha.token`, and the tinytuya wizard's output. **None of them ever goes into a repo.**
`kwh_total` is the plug's `add_ele` counter — energy since the plug last reported to the cloud, not a
lifetime total. Use watts × time for energy.
When the plug moves address or is paired again: re-run the tinytuya wizard in `~/.config/felhom-bench/`
(credentials `TUYA_ID`, `TUYA_SECRET`, `TUYA_DEVICE_ID` from `~/.config/credentials`, region `eu`) and
update `plug.json`. Its output prints the key — send it to a file, never to a terminal or a log.