Bench: plugmeter reads the N100's metered plug (tinytuya + Home Assistant from the catalog)
gates / gates (push) Successful in 6m43s
gates / gates (push) Successful in 6m43s
scripts/bench/plugmeter.py prints watts/mA/V/kWh as CSV from the Tuya plug on the LAN (default) or from Home Assistant on demo-hp's guest. 10-minute side by side and a 3-minute control in documentation/audits/plugmeter-2026-10-13/: Home Assistant alone did not move for 3 minutes, so the LAN reader is the measurement source. No key, device id or token in the repo; secrets scan 0 hits with a positive control.
This commit is contained in:
1 parent
fc0441348d
commit
6a1f715a87
9 files changed
+915
No files matched your search
@@ -0,0 +1,33 @@
|
||||
# scripts/bench — bench tools that run on DooPlex
|
||||
|
||||
## plugmeter.py — the N100's power meter
|
||||
|
||||
The N100 demo box (`demo-felhom`) is on a Tuya Wi-Fi plug with a power meter. `plugmeter.py` reads it and
|
||||
prints CSV (`utc_time, watts, milliamps, volts, kwh_total`) every `--interval` seconds (default 2).
|
||||
|
||||
```
|
||||
~/.venvs/plugmeter/bin/python scripts/bench/plugmeter.py --once # one reading
|
||||
~/.venvs/plugmeter/bin/python scripts/bench/plugmeter.py --duration 600 > a.csv # 10 minutes
|
||||
~/.venvs/plugmeter/bin/python scripts/bench/plugmeter.py --source ha --once # through Home Assistant
|
||||
```
|
||||
|
||||
- **`--source tuya` (default) — use this for measurements.** It talks to the plug on the home LAN and
|
||||
makes it re-measure on every read; a new value every 2 s. Each value is the plug's previous measurement
|
||||
(it answers a refresh with what it holds), so a row lags by about one interval. About one read in four takes
|
||||
up to 8 s instead of 2 s; the row is late, not lost.
|
||||
- **`--source ha` — the backup.** Home Assistant on demo-hp's guest (`https://ha.enkisfelhom.hu`, installed
|
||||
from the Felhom catalog) reads the plug through Tuya's cloud. **On its own it did not change for 3 minutes**
|
||||
(2026-10-13); it moves only when something makes the plug report — the tuya reader does. It keeps history and graphs. Its `felhom-bench` user is local-access-only, so the tool connects
|
||||
to the guest's LAN address and still checks the certificate by name.
|
||||
|
||||
Setup (done 2026-10-13, `documentation/audits/plugmeter-2026-10-13/`): a user venv
|
||||
(`python3 -m venv ~/.venvs/plugmeter && ~/.venvs/plugmeter/bin/pip install tinytuya`), and the files under
|
||||
`~/.config/felhom-bench/` (700; every file 600): `plug.json` (device id, local key, address, data points),
|
||||
`ha.json`, `ha.token`, and the tinytuya wizard's output. **None of them ever goes into a repo.**
|
||||
|
||||
`kwh_total` is the plug's `add_ele` counter — energy since the plug last reported to the cloud, not a
|
||||
lifetime total. Use watts × time for energy.
|
||||
|
||||
When the plug moves address or is paired again: re-run the tinytuya wizard in `~/.config/felhom-bench/`
|
||||
(credentials `TUYA_ID`, `TUYA_SECRET`, `TUYA_DEVICE_ID` from `~/.config/credentials`, region `eu`) and
|
||||
update `plug.json`. Its output prints the key — send it to a file, never to a terminal or a log.
|
||||
Reference in new issue
Block a user