hub-db-backup: wait for a snapshot being written, limit 7 h (one slot gap + 1 h) — the 2 h limit refused the hub's own catch-up and mailed a false failure at 10:28 (R-1234, closed); tests red-proved
gates / gates (push) Successful in 13m14s
gates / gates (push) Successful in 13m14s
This commit is contained in:
@@ -26,6 +26,12 @@
|
||||
|
||||
---
|
||||
|
||||
## 2026-10-23 day — the releases and the DooPlex hour (the operator's „go")
|
||||
|
||||
| Row | What | Closed | Evidence |
|
||||
|---|---|---|---|
|
||||
| **R-1234** | **D34's first push refused the hub's own catch-up and mailed a false „hub-db-backup failed" to admin@.** Installing the 6-hourly timer at 10:28 made systemd catch up the missed 08:30 slot at once (`Persistent=true`), while the freshly deployed hub 0.167.0 was still writing its start-up snapshot (`hub-*.db.tmp`); the only finished one was 02:00 (8 h), above the new 2-hour limit → „the hub stopped snapshotting", `OnFailure` mail id `01a167e0…`. The 2 h limit was also stricter than the hub's own 6-hour catch-up, so any restart could repeat it. (P3) | CLOSED 2026-10-23 day, the same session — the push waits (≤ 20 min) for a snapshot being written, and the limit is one slot gap + 1 h (7 h); tests `test_d34_waits_for_a_snapshot_being_written` (reproduces the 10:28 run when the wait is removed), `…_a_restart_within_one_slot_is_not_an_alarm`, `…_two_missed_slots_are_refused`, each red-proved | `audits/day-2026-10-23/13-hubdb-6h-D34.txt` |
|
||||
|
||||
## 2026-10-22 night — the seven decisions put into effect (full text of the rows: `git show 1100a344:documentation/backlog/OPEN-ITEMS.md`)
|
||||
|
||||
| Row | What | Closed | Evidence |
|
||||
|
||||
Reference in New Issue