docs: 07 §6.3 the put-back covers every restore and a power cut (D22, as built and proven on 9202); 03 guest swap = RAM and the host's swap behind it; capability map D16; soak provenance
gates / gates (push) Failing after 14m51s

This commit is contained in:
admin committed 2026-10-21 23:00:45 +02:00
1 parent 6b0d23c29c
commit 2293b252d5
6 files changed
+86

No files matched your search

@@ -181,6 +181,7 @@
| <a id="d13"></a>[D13](capability-map-detail/D.md#d13) | Media apps see EVERY drive; a drive added, pulled, back or safely removed is handled per app (notice, real restart, wiring, torrents paused/resumed) | controller v0.313.0, catalog `0188430`, hub v0.151.0 | **PROVEN-LIVE** | Tier-0 boxes (Tester 1, demo-hp 9201); the fleet with golden 0.313.0 + the floor | `audits/media-build-2026-10-15/G/` (2026-10-15); `audits/media-drive-events-2026-10-14/` (2026-10-14) |
| <a id="d14"></a>[D14](capability-map-detail/D.md#d14) | A second local copy COUNTS only on a proven different physical disk: the agent knows each place's disks; a VM box makes the copy but says it cannot check; a same-disk copy is not made; a NAS never hides the one-copy notice; a box with no drive refuses a data-folder app in words | agent v0.157.0, controller v0.317.0, hub v0.154.0 | **PARTIAL** | live: VM `unknown` (Tester 1) and two real-disk boxes `proven` (demo-hp, N100); unit only: the same-disk skip, the NAS notice, the no-drive sentence; `usb_bridge` never seen on a device | `audits/storage-identity-buildA-2026-10-15/README.md` (2026-10-15); `architecture/16-storage-physical-identity.md` §13 |
| <a id="d15"></a>[D15](capability-map-detail/D.md#d15) | A one-disk box gets its own data area („Belső tárhely") outside every whole-box copy, registered as the default drive with no press, so media and data-folder apps install with no extra step; a free disk's partitions can be formatted or used one by one | installer 1.33.0, agent v0.158.1, controller v0.318.0, golden 0.318.0 | **PROVEN-LIVE** | fresh 512 GB one-disk VM on demo-hp; partitions on a scratch disk; the old-box signed job and the D4 sentence unit-proven only; an empty part asks for confirmation (R-1093) | `audits/storage-identity-buildB-2026-10-15/README.md` (2026-10-16) |
| <a id="d16"></a>[D16](capability-map-detail/D.md#d16) | A failed or cut restore puts the household's data back EXACTLY as it was and starts the app — local unit, second drive, kept load and off-site, and after a power cut or a killed controller (D22) | controller `main` (0.338.0-rc.1), unreleased | **IMPLEMENTED** | proven live on 9202 (rc.1): a damaged unit and a controller killed between the volume step and the replay; the second-drive pre-check (R-1178), the mirror skip (R-1180) and the off-site power cut by test only; a database outside the replaced volumes is not covered | `audits/night-2026-10-21/P3-restore/02-run.log` (2026-10-21) |
## E. Access, networking & household use