# Alarm truth table — CHAOS NIGHT 2026-09-17 (draft, rounds 1-7; 8-12 appended as they close)
# Built from the verdicts recorded in each round's write-up, not from a fresh grep.
# Columns: round | accident | alarms that FIRED | all true? | any that SHOULD have fired and did not

R1 | none (control)        | app_start_failed; backup_run_failures; offbox_repo_orphaned | YES (3/3) | none
R2 | power cut mid-restore | controller_started (info)                                   | YES (1/1) | none - 60s outage is under both thresholds (node_stale 30m, boot grace 90s)
R3 | system disk 96% / 10m | none                                                        | n/a       | none MISSING, but see note: disk_critical is defined at >=95% and never fired, because
   |                       |                                                             |           | the fill-watch is a DAILY sweep (03:30) + one check ~90s after a controller start.
   |                       |                                                             |           | Predicted BEFORE the round, confirmed after. Filed as R-547 (P3), not a false alarm.
R4 | tunnel killed 10m     | health_critical (error) -> health_recovered (info)          | YES (2/2) | none
R5 | docker restarted      | controller_started (info)                                   | YES (1/1) | none - 90s boot grace covers the app restarts
R6 | none (control)        | whole_guest_backup_failed (error)                           | YES (1/1) | none - and it named the TIER ("local tier"), not "the backup".
   |                       |                                                             |           | No alarm for the 22 apps the backup stopped: correct, those stops are suppressed.
R7 | internet cut 10m      | none                                                        | n/a       | none - node_stale threshold is 30m, the cut was 10m. Nothing false raised either.

## Running totals, rounds 1-7
  alarms fired:            8
  alarms TRUE:             8   (8/8 - no false alarm all night so far)
  alarms MISSING:          0
  design gaps found:       1   (R-547: a transient full disk is never mentioned to anyone)

## Two traps avoided, recorded so the numbers can be trusted
  R3: "none fired" was checked TWICE, independently, after the fill was released.
  R5: the first alarm snapshot was taken 6 s after the controller start. An alarm cannot be
      called missing by a measurement taken before it could possibly have fired. Re-measured.