admin fd28d70bff v0.308.0: controller batch 2026-10-12 — clear-address warning (R-922), secret sweep over every page (R-255), read_failed (R-266), no NVMe heat band (R-333), share globe (R-577), Hungarian dates and numbers (R-562), lost-drive option pinned (R-521)
Operator rulings 2026-10-12, 09 §3 decisions 196, 204-207, 223, 227. MinAgent 0.131.0 unchanged.
R-255's sweep found one leak, fixed here: an optional-config secret_input was rendered into its
settings page; it is now revealed on demand. Hungarian parity fixtures re-captured once for R-562.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_0159rPz1ZhFKsS53msqPYxtS
2026-10-12 15:13:59 +02:00

37 lines
2.1 KiB
Go

package agentapi
import "testing"
// R-333 (`09` §3 decision 206): no heat band for an NVMe drive. Both directions, because "fixed" means
// one kind of drive stopped alarming on heat and the other did not, and the drive's own alarm stays.
func TestDiskVerdict_NVMeHasNoHeatBand(t *testing.T) {
noPrior := DiskPrior{}
cases := []struct {
name string
in *SmartSummary
want DiskVerdict
}{
// A healthy NVMe under load: 72 °C, the device raises no flag. No heat alarm.
{"hot NVMe, no critical warning → ok", &SmartSummary{Health: SmartPassed, TemperatureC: ip(72), CriticalWarning: ip(0), PercentageUsed: ip(3), MediaErrors: ip(0)}, DiskVerdictOK},
{"warm NVMe 56 °C, no critical warning → ok", &SmartSummary{Health: SmartPassed, TemperatureC: ip(56), CriticalWarning: ip(0)}, DiskVerdictOK},
// The same drive with its own temperature bit set (critical_warning bit 1 = 0x02): Hiba.
{"hot NVMe with critical_warning temperature bit → fail", &SmartSummary{Health: SmartPassed, TemperatureC: ip(72), CriticalWarning: ip(2)}, DiskVerdictFail},
{"cool NVMe with critical_warning → fail", &SmartSummary{Health: SmartPassed, TemperatureC: ip(40), CriticalWarning: ip(1)}, DiskVerdictFail},
// Spinning/SATA drives keep their 55/60 °C bands, unchanged.
{"SATA 56 °C → warn", &SmartSummary{Health: SmartPassed, TemperatureC: ip(56), ReallocatedSectors: ip(0)}, DiskVerdictWarn},
{"SATA 60 °C → fail", &SmartSummary{Health: SmartPassed, TemperatureC: ip(60), ReallocatedSectors: ip(0)}, DiskVerdictFail},
{"SATA 54 °C → ok", &SmartSummary{Health: SmartPassed, TemperatureC: ip(54)}, DiskVerdictOK},
}
for _, c := range cases {
if got := DiskVerdictFor(c.in, noPrior); got != c.want {
t.Errorf("%s: DiskVerdictFor = %s, want %s", c.name, got.Label(), c.want.Label())
}
}
// The alert body must not name heat as the reason for an NVMe drive.
for _, a := range DegradedAttributes(&SmartSummary{Health: SmartPassed, TemperatureC: ip(72), CriticalWarning: ip(2)}) {
if a == "hőmérséklet" {