c1a63de1c7
NotifyStorageDisconnected and NotifyStorageReconnected were defined and called from NOWHERE. Registered in allowedEventTypes, in DefaultEnabledEvents, and given a Hungarian message on the hub -- and never invoked. A drive going absent produced apps stopped, a WARN log and a UI badge, then silence on every channel. Verified against the gitignored-cmd/ trap with a positive control. Fifth instance of this class, found by E-2 Phase 0 rather than by a failure. A drive that is ONLY a backup target has no apps to stop, so it was silent twice. ReconcileDriveGates now calls both halves. When the absent drive is the whole-guest backup target it raises the more specific backup_target_absent (error) instead -- never both, since two mails for one event trains people to ignore the channel -- and recovers as backup_target_restored (info, the existing pairing-gated pattern; severityNotifies NOT widened). The recovery mirrors the alarm's choice or the operator cannot match them. Which drive is the target comes from the AGENT (/disks backup_target, >= 0.112.0), not from our StoragePath.BackupTarget: that is customer INTENT, and on the two boxes migrated by hand in E-1 the intent was never recorded while the drive really is the target. An older agent omits the field -> false -> generic alarm, never a wrong one. Before this an absent backup target had NO prompt signal: the tier stays DUE (targetStoragePresent checks name presence, never reachability), so the only evidence was its own failure at the next due cycle, up to ~24h away. The R-100 shape. Tests observe the WIRE, not a mock, because the failure class is "nothing arrives": a real Notifier posts to an httptest hub and the test asserts the event type and severity that actually went out. MinAgent: 0.112.0 Green gate: build + vet + test rc=0 (27 packages), run separately from this commit.