d8c2634472
Each quiesce window now backs up ONLY the first due tier that starts and resumes the apps at its snapshotted; the upload finishes with the apps running. Any other due tier stays due and a later cycle (the next poll) takes it in its own short window - never straight after the first. This reverses R-82's 'ONE quiesce window for both due tiers'. A manual press (TriggerNow) backs up the primary (local) tier only, picked by the agent's Primary flag; the off-site tier follows at the next scheduled night run. If no available tier is flagged primary, the first available tier is backed up rather than nothing. Unchanged: marker written before any stop, one unquiesce per window, the max-quiesce bound, BUSY/start-error handling (the next tier is still tried in the same window when a tier does not start), breaker and contention. Tests: TestBothTiersDue_ExactlyOneQuiesceWindow -> TestBothTiersDue_FirstCycleRunsOnlyFirstTier; TestNonLastTierSnapshot_ DoesNotResumeApp -> TestFirstTierSnapshot_ResumesAppWhileUploadContinues (red on old code); new TestManualPress_RunsOnlyLocalTier (red on old code), TestLeftoverTier_RunsInNextCycleInItsOwnWindow, TestManualRunTiers_NoPrimaryAvailable_BacksUpFirstAvailable; TestNotify_BothFailingTiersAreReported now runs two cycles. Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_0159rPz1ZhFKsS53msqPYxtS