controller v0.267.0: tests off DooPlex's Docker, cut-off copies refused, two pages true
R-650: internal/dockerexec — every docker exec routed through it; under
go test a real docker is refused (opt-in FELHOM_TEST_REAL_DOCKER=1; a stub
under the temp dir is allowed). api/stacks/web tests run under a silent
stub (TestMain). TestR650_NoBareDockerExec pins it repo-wide.
R-640: a dump without its engine's completion marker is refused before
the first mutation (unit + off-site restore) and again before any load.
R-499: the Tier-2 page's system-disk sentence has four true branches.
R-518: the backup button states the measured ~8 min stop.
R-626: measured on 9202, not reproduced.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_0159rPz1ZhFKsS53msqPYxtS
2026-09-23 20:25:28 +02:00

3.2 KiB
Raw Blame History

REPORT — controller v0.267.0: tests off DooPlex's Docker, cut-off copies refused, two pages true (2026-09-23)

Night shift 2026-09-23, Part A. R-650, R-640, R-499, R-518; R-626 measured. MinAgent 0.131.0 (unchanged). No hub change. Full night record: felhom.eu/documentation/audits/DRILL-night-2026-09-23.md; evidence felhom.eu/documentation/audits/night-2026-09-23/A*.

Not done, or changed

  • R-518: the brief said the page promises „csak néhány másodpercre". It does not — v0.243.0 removed that. The remaining vague „általában néhány perc" is replaced by the measured ~8 minutes.
  • R-626: not reproduced, so not "fixed" — closed by measurement (below).
  • R-640's "narrowed" scope held: the undo copies folders; only the three restore paths load dumps.

What shipped

  • R-650: internal/dockerexec (Command/CommandContext/RunWithStub). 77 docker exec sites routed through it. The sweep (trace of the guard's refusals, A1-r650-sweep.txt): web 67× docker compose version, 19× docker ps, 19× docker info, 10× docker inspect felhom-samba, 2× docker exec felhom-samba; backup 46× docker ps; stacks 11× compose ps, 4× docker ps, 1× docker-compose down; appexport 7× docker ps; system 1× docker info; 8 api tests FAILED on the refusal (they built a real Manager). api/stacks/web → TestMain + RunWithStub; the rest pass on the refusal.
  • R-640: appbackup.CheckDumpComplete; incompleteDumps gate in RestoreFromRecoveryUnit and ReconstituteFromOffsite before the first mutation; a second check in reimportDBDumpsFrom before any load. Test fixtures' fake dumps now end with the real markers (they did not — 38 tests red first).
  • R-499: systemBackupFact(resolveBackupTargetState) → four branches on the Tier-2 page.
  • R-518: two bundle strings, both languages, state the measured stop.

Red-proofs (8, each seen failing, then restored; git diff clean on the reverted file)

  1. R-650 guard disabled → TestR650_RealDockerIsRefusedUnderGoTest: got <nil>.
  2. R-650 one bare exec.CommandContext(ctx, "docker"…) put back in dbdump.go → the sweep names dbdump.go:140.
  3. R-640 replay check removed → a cut-off copy was LOADED.
  4. R-640 unit gate removed → stopped=true calls=[stop recreate startsvc:immich-postgres start].
  5. R-640 off-site gate removed → the replay check still caught it, then a rollback — not the clean refusal.
  6. R-499 handler not passing the fact → three branches missing on the page.
  7. R-499 old sentence in the same-disk branch → promises the backup protects this app.
  8. R-518 bundles back to v0.243.0 → measured downtime appears 0 times, old wording present.

R-626, measured on 9202 (v0.266.0)

navidrome deployed and removed through the product; docker events for its compose project 390 s: kill/stop/die/destroy seen (the positive observable), no create. Controller restarted at +150 s; guest rebooted after. 0 containers, 0 volumes at every check. Leftover: applied-compose.yml + applied-meta/ stay in the stack dir after a remove (row filed).