REPORT — felhom-controller: slice 10 (external user-data drives) — controller side

Version: 0.50.0 · Date: 2026-06-12 · pairs with felhom-agent v0.25.0v0.27.0

The controller's half of slice 10 (the agent owns the host-side execution + self-heal; see felhom-agent's REPORT for P1 spike / P2 passthrough / P2 activation endpoint / P3 self-heal). All live-validated on guest 9201; golden rebaked to 0.50.0.

P2C — enroll passes the drive into the guest (v0.48.0)

  • agentapi.GuestAttach(where) → agent POST /disks/guest-attach. runStorageInit / runStorageAttach / handleStorageRegister call attachIntoGuest after recording the StoragePath (best-effort; a transient failure is logged — P3 self-heal completes it). Closes Branch A: an enrolled drive becomes usable in the guest (app HDD_PATH writes land on /dev/sdb1; the "nem elérhető" banner clears).

Activation-UX (v0.49.0)

  • The host-side live inject is blocked on unprivileged LXC, so a drive enrolled into a running guest activates at the next guest boot. Per decision: enroll persists (no forced reboot) + a user-triggered restart.
  • pendingActivationDrives() flags registered drives the agent reports present+attached but which aren't a live mount in the container. The settings page shows a banner + a batched "Újraindítás most (~30 mp)" button → POST /api/storage/activateagentapi.GuestReboot → agent POST /guest/reboot. Live-validated: activate → guest reboots → drive active.

P4 — dual-role drives + backup-aware wipe warning (v0.50.0)

  • 4A: a user-data drive is appdata AND backup-target-eligible (not locked to one role) — surfaced in the drive overview's per-card purpose note. felhom-pbs/system/backup roles unchanged.
  • 4B: handleStorageImpact now also returns backup_copies — apps whose cross-drive (secondary) backups are stored on the drive (backupCopiesOnPath scans felhom-data/backups/secondary/<app>, skipping the shared restic repo / _infra). The type-to-confirm wipe/eject modal names them ("Ez a meghajtó más alkalmazások biztonsági másolatait is tárolja — a törlés ezeket is eltávolítja"). The wipe stays customer-confirmable (the copies are redundant; originals live on the source drive).
  • OUT OF SCOPE: the cross-drive backup ENGINE (restic USB1↔USB2, scheduling, pruning) — a follow-on slice (needs a 2nd physical drive to validate). The 4B detection is forward-compatible (empty until the engine writes there).

Live validation (9201)

  • P2C: app bytes on /dev/sdb1, banner [PASS] 1 connected, 0 disconnected.
  • Activation: /api/storage/activate → reboot → drive active.
  • P4: /api/storage/impact?where=/mnt/felhom-usbbackup_copies:[]; after creating felhom-data/backups/secondary/immichbackup_copies:["immich"] (detection live).
  • go test ./internal/{web,agentapi}/ green; golden rebaked to 0.50.0, build guest purged.

Note (carried from P2)

The controller's app/backup path helpers still join felhom-data under the registered drive path; in Model A the in-guest mount IS the felhom-data namespace, so backup paths double-nest (felhom-data/felhom-data/...) — functional but untidy. Reconcile when wiring app-data-backup-to-drive (not in this slice; app HDD_PATH data lands correctly today).