NotifyStorageDisconnected and NotifyStorageReconnected were defined and called
from NOWHERE. Registered in allowedEventTypes, in DefaultEnabledEvents, and given
a Hungarian message on the hub -- and never invoked. A drive going absent produced
apps stopped, a WARN log and a UI badge, then silence on every channel. Verified
against the gitignored-cmd/ trap with a positive control. Fifth instance of this
class, found by E-2 Phase 0 rather than by a failure.
A drive that is ONLY a backup target has no apps to stop, so it was silent twice.
ReconcileDriveGates now calls both halves. When the absent drive is the whole-guest
backup target it raises the more specific backup_target_absent (error) instead --
never both, since two mails for one event trains people to ignore the channel --
and recovers as backup_target_restored (info, the existing pairing-gated pattern;
severityNotifies NOT widened). The recovery mirrors the alarm's choice or the
operator cannot match them.
Which drive is the target comes from the AGENT (/disks backup_target, >= 0.112.0),
not from our StoragePath.BackupTarget: that is customer INTENT, and on the two
boxes migrated by hand in E-1 the intent was never recorded while the drive really
is the target. An older agent omits the field -> false -> generic alarm, never a
wrong one.
Before this an absent backup target had NO prompt signal: the tier stays DUE
(targetStoragePresent checks name presence, never reachability), so the only
evidence was its own failure at the next due cycle, up to ~24h away. The R-100
shape.
Tests observe the WIRE, not a mock, because the failure class is "nothing
arrives": a real Notifier posts to an httptest hub and the test asserts the event
type and severity that actually went out.
MinAgent: 0.112.0
Green gate: build + vet + test rc=0 (27 packages), run separately from this commit.