The unit's data files are stamped with the versions that wrote them; the capture keeps the
definition the data belongs to; a restore never starts data under another version's
definition (unit restores refuse a mismatch; the off-site restore writes the snapshot's
definition); every tier's time is its data's; the conversion-copy release needs a dump on
the new engine. File-browser sync single-flight + no empty kept folder (R-695); the kept
view joins the folder's owning group, language switch resyncs (R-691); a restore-generated
login is not shown as the password (R-694). Red-proofs in
felhom.eu/documentation/audits/version-travel-2026-09-26/.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_0159rPz1ZhFKsS53msqPYxtS
R-167: new internal/fillwatch warns the CUSTOMER before a filesystem fills.
It emits the PRE-EXISTING disk_warning/disk_critical pair, which was
allowlisted, copy'd, default-enabled and checkbox'd with no producer in any
repo — the sixth "built but never wired" instance here. Two threshold terms
(85% or 5 GiB free; critical 95%/2 GiB) because a percentage alone lies at
both ends of this fleet's size range. Edge-triggered on escalation only,
state persisted, hysteresis dead zone at 75%/7 GiB pinned by a test. A nil
usage read is never a warning and never clears one. Per filesystem, never
per app. Daily 03:30, before the nightly app-data legs.
R-158: new unitNotify seam fires per app when a Tier-1 recovery-unit capture
fails, loop continuing, carrying the target filesystem's used/free bytes.
Operator-tier (recovery_unit_capture_failed) — deliberately NOT backup_failed,
which is customer-enabled and would email the customer about a failure they
cannot act on. D-c overrides R-158's own proposal here.
R-174: the app-stop guard no longer starts apps onto MISSING drives — a
regression in v0.189.0 code, found by review and closed the same session.
SetStarter got the raw stack manager, whose StartStack has no drive gate,
and Recover runs at startup. R-171 one path over. bootDriveGate could not be
reused whole (its holder #2 is the guard's own marker, and holders #1/#2 read
vars assigned after Recover runs), so holder #3 is extracted into a shared
driveStartGate with a test pinning the delegation. ErrStartRefused splits a
refusal from a failure: both keep the marker, only Failed alarms, because
routing a deliberate hold into NotifyBackupFailed is the same false alarm.
Tests 1157 -> 1184. All red-proofs demonstrated failing and restored.