Files
felhom-agent/REPORT.md
T
admin a165d53c88
gates / gates (push) Successful in 49s
REPORT: the second burn-down night
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_0159rPz1ZhFKsS53msqPYxtS
2026-10-07 00:14:50 +02:00

1.3 KiB

REPORT — the second burn-down night (2026-10-06 → 07): R-894 and the R-330 wire half, on main, unreleased

Nothing was released or delivered (brief fence). Both changes ship with the memory-kill check as v0.150.0, after the 2026-10-07 night read-back. Session report: felhom.eu/REPORT-night-burndown-2026-10-06.md; night log felhom.eu/documentation/audits/night-burndown-2026-10-06/NIGHT-LOG.md.

  • R-894 (74b5eae): the newest successful backup per tier is kept on disk (backup-success-state.json in the OOB state dir) and read by /backup/due only when the tier's storage cannot be read: fresh → not due, older than the cadence → due, none → due with age unknown (as before). A storage that answers stays the ground truth. Tests TestBackupDue_R894_*, TestBackupSuccessState_*, TestR894_LastKnownBackupsIsWiredIntoTheDaemon; four red-proofs felhom.eu/documentation/audits/night-burndown-2026-10-06/s4/. Architecture: 07 §6.1 updated.
  • R-330, wire only (adaf86a): the host report's SMART summary carries 187 reported_uncorrect, 188 command_timeout, 199 udma_crc_errors (pointers, omitted when unknown). No verdict reads them.
  • Suite go test ./... rc 0; scripts/agent_gates.py (full) all OK; CI green on each push (runs 1451, 1467).