Commit Graph

3 Commits

Author SHA1 Message Date
admin 4463243f2e Upgrade harness: four fixtures and seven real upstream edges from the update night (R-462)
gates / gates (push) Successful in 1s
Test code only — no template changed and no image: line moved.

The update night walked real within-a-major upstream edges on scratch guest 9202 through the
product's own guarded Update, against a PRIVATE DRILL CATALOG; the live catalog was never
touched. This brings the expensive half of that work — the seed routes — back into the harness
so the same edges can be run here WITH their ABORT step, which the box deliberately does not
offer (09 6.1: whether the old image starts on migrated data is per-app and unpredictable).

- upgrade_fixtures.py: ActualBudget, Navidrome, AudiobookShelf, Vikunja. Each seeds through the
  app's OWN interface (R-156); each carries a negative control run on every verify(), so a
  readback that has broken into always succeeding fails instead of passing everything.
- upgrade-test.py: edges U1..U7, all real upstream moves existing 2026-09-21 that this catalog
  has NOT made, each holding its database engine constant.
- Limitations kept: Navidrome and AudiobookShelf seed the DATABASE half only, and say so.

OWED, stated so it is not mistaken for done: the U1..U7 harness RUNS, and with them the per-app
ABORT answers. The code is in; the runs are not.

Gates: catalog_gates.py --fast — image-pins, engine-major, catalog-since, copy-i18n all OK.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_0159rPz1ZhFKsS53msqPYxtS
2026-09-21 21:00:50 +02:00
admin b7ef0c4a09 upgrade-test.py: record the engine's own view of its datadir, beside the verdict
gates / gates (push) Successful in 1s
R-459. The harness returned proven for E3b while MariaDB was logging that the
conversion it requires had been skipped. The verdict was right - the app's data
survived, which is what it asked - but the harness watched the app and the
migration log, and neither looks at engine state.

engine_state_after now carries each database service's own answer: MariaDB's
datadir version plus 'mariadb-upgrade --check-if-upgrade-is-needed', and
PostgreSQL's PG_VERSION.

It sits BESIDE the verdict and is never folded into it. An unconverted datadir is
not known to be a failure - 5 of 5 restarts showed no degradation - so a verdict
that called it failed would encode an unproven judgement, which is worse than
reporting a fact and letting a person read both.

No template changed. Nothing with MARIADB_ in it is committed by this work: that
is a fleet-wide decision the operator owns, and it affects four apps.
2026-09-06 17:38:50 +02:00
admin 0474ce387e upgrade-test.py: measure whether a real app upgrade keeps the customer's data
gates / gates (push) Successful in 0s
R-449. Until today one upgrade out of 53 had ever been measured - Nextcloud, by
hand, in a spike - and the whole update arc was designed against that single data
point.

Per edge: deploy at FROM, seed through the app's OWN interface, prove the seed
reads back, swap to TO, ask the app for the data again, then put the FROM images
back and record what happens - verbatim, and never called a rollback.

Success is an application-level readback, not file identity: survive2.py's
sha256+inode rule is right for a redeploy and wrong for an upgrade, because a
migration is supposed to rewrite files. And nothing is ever seeded by hand (R-156)
- an app with no non-browser route is recorded inconclusive, never faked.

C3 is a negative control whose TO image exits immediately, and it must be run
first: it came back failed, which is what makes the greens mean anything.

The bookstack fixture uses artisan for both halves and carries its own negative
control on every call, because the obvious HTTP-login readback cannot work: the
template's https APP_URL makes the session cookies secure, so curl over http gets
419 on every login and it looks exactly like a wrong password.
2026-09-06 11:44:18 +02:00